HI-6153 Electric Field Probe
ETS-Lindgren's Model HI-6153 Laser-powered Electric Field Probes provide broadband EMF frequency coverage and wide dynamic range that satisfies the demands of most test requirements. 

 

 


ETS-Lindgren's Model HI-6153 Laser-powered Electric Field Probes provide broadband EMF frequency coverage and wide dynamic range that satisfies the demands of most test requirements. To take advantage of this capability, the HI-6153 was designed to be single range reading so data can be read continuously over the entire dynamic range. Data values for each axis (X,Y,Z) can be read individually, or summed.

​Fiber optic signal and power lines link the model HI-6153 probe to either the model HI-6100 Field Monitor, or as a direct connect to a PC USB port with the HI-6113 Laser Data Interface and ProbeView™ Laser Software.

The HI-6100 provides manual functions and programmed control via IEEE-488 and RS-232 Serial Data Interfaces. Readings from up to four probes can be displayed simultaneously.

The EMCenter™ Modular RF Platform along with the EMSense™ interface card can be used with the HI-6000 series field probes as a field monitor in addition to its capability as a system level platform.

The HI-6113 provides the laser power and communications for the HI-6153. A USB connection to the PC allows for quick and easy data collection, using ProbeView Laser software.

Key Product Information


Specifications Select a tab below for more information



Detection Isotropic: (X, Y, and Z Axis Readings)
Frequency Range: 10 MHz to 40 GHz
Frequency Response with Correction:

  • 10 MHz to 18 GHz ± 0.9 dB
  • 18 to 40 GHz ± 1.1 dB

Frequency Response (Typical): 

  • 10 to 100 MHz + 3.0, -4.0 dB
  • 100 MHz to 1 GHz +3.0, -0.50 dB
  • 1 to 18 GHz +4.0, -2.0 dB
  • 18 to 40 GHz +3.5, -4.5 dB

Dynamic Range: 2 to 800 V/m (Single Range)
Resolution:  0.01 V/m
Isotropic Deviation: ±1.0 dB < 18 GHz
Linearity: ±0.5 dB   
Sample Rate (Typical): 70 Samples per Second Maximum
Overload Withstand: >1500 V/m CW

Physical Interface:

  • Duplex Optical Fiber (62.5 Micron Multimode)
  • FC Connectors for Laser Cable, Integral 1m Optical Cable
  • ST Connector for Transmitter Cable, Integral 1m Optical Cable 
Operating Temperature Range: 10° to 40° C (50° to 104° F); 5-95% Relative Humidity Non-condensing 
Length: 43.8 cm (17.24 in) 
Width: 5.7 cm(2.24 in) 
Weight: 0.36 kg (12.64 oz) 
Mounting: 1/4 in x 20 UNC Internal Thread
  • Probe Assembly
  • A2LA Traceable Calibration Report
  • 10m Fiber Optic Cable
  • Bulkhead Connectors (2)
  • Carrying Case
  • Fiber Cleaning Kit and Swabs
  • Manual
  • Optical Cable Extensions (H-491263-xx)
  • HI-6100 Field Monitor Interface Card (H-491277)
  • Fiber Optic Maintenance Kit (112333)
  • Probe Stand Assembly (H-491269)
  • Extra Probe Carriers for Above Probe Stand (H-491276)
  • EMCenter Interface Card (125428) 
​ ​​




 

 

HI-6105 Electric Field Probe http://www.ets-lindgren.com/products/probes-monitors/emc-probes/electric-field-probes/9003/900304HI-6105 Electric Field Probe
HI-6006 Electric Field Probe with Field-Replaceable Battery http://www.ets-lindgren.com/products/probes-monitors/emc-probes/electric-field-probes/9003/900307HI-6006 Electric Field Probe with Field-Replaceable Battery
HI-6053 Electric Field Probe http://www.ets-lindgren.com/products/probes-monitors/emc-probes/electric-field-probes/9003/900303HI-6053 Electric Field Probe
HI-6023 Electric Field Probe with Field-Replaceable Battery http://www.ets-lindgren.com/products/probes-monitors/emc-probes/electric-field-probes/9003/900308HI-6023 Electric Field Probe with Field-Replaceable Battery
HI-6122 Electric Field Probe http://www.ets-lindgren.com/products/probes-monitors/emc-probes/electric-field-probes/9003/900305HI-6122 Electric Field Probe
HI-6153 Electric Field Probe http://www.ets-lindgren.com/products/probes-monitors/emc-probes/electric-field-probes/9003/900306HI-6153 Electric Field Probe

Key Features


  • Laser Powered for Unlimited Test Time 
  • Frequency Range: 10 MHz to 40 GHz 
  • Dynamic Range: 2.0 to 800 V/m (Single Range) 
  • Provides Individual and Summed Axis Values 
  • A2LA Accredited Calibration Report 
  • Suitable for MIL Standard Specs: 
    • MIL-STD 461F Radiated Susceptibility (RS)
  • Suitable for Automotive Specs:
    • SAE J1113/27
    • GMW 3091/3097/3103
    • FORD FMC 1278
  • Suitable for Commercial Specs:
    • EN/IEC 61000-4-3 Radiated Immunities
  • Operates with Most 3rd Party Immunity Software

Literature and Videos


 

 

http://www.ets-lindgren.com/products/probes-monitors/emc-probes/electric-field-probes/9003/900306<a href="/sites/etsauthor/ProductBrochures/General%20Brochures/Test_and_Measurement_Full_Line.pdf"><img alt="" src="/_layouts/15/IMAGES/icpdf.png" />Test_and_Measurement_Full_Line.pdf</a>

 

 

http://www.ets-lindgren.com/products/probes-monitors/emc-probes/electric-field-probes/9003/900306

L o a d i n g

 Catalog-Item Reuse