Key Features

  • Frequency Response: 10 kHz to 1 GHz
  • Dynamic Range: 2.0 to 800 V/m
  • Provides Individual and Summed Axis Values
  • A2LA Accredited Calibration Report
  • Suitable for MIL Standard Specs:
    • MIL-STD 461F Radiated Susceptibility (RS)
  • Suitable for Automotive Specs1:
    • SAE J1113/27
    • GMW 3091/3097/3103
  • Suitable for Commercial Specs:
    • EN/IEC61000-4-3 Radiated Immunity
  • Operates with Most 3rd Party Immunity Software
  • Watch Product Video

1 For High Field and High Frequency Requirements, the HI-6053 is Recommended
  • Download PDF Datasheet
  • ETS-Lindgren's Model HI-6023 RF Field Probe is a fully intelligent sensor enabling fast and accurate EMF measurements with industry-leading performance specifications. Optical coupling to a variety of readout options makes this probe ideally suited for a wide range of field monitoring applications.

    Designed to be single range reading, the HI-6023 can read data continuously over the entire dynamic range. Data values for each axis (X, Y, and Z) can be read individually or summed.

    A unique feature of the HI-6023 is the field-replaceable battery. This battery allows the user to replace the battery when necessary, without requiring additional calibration. Simple in-field synchronization of the HI-6023 is all that is required for proper battery level monitoring.

    The EMCenter Modular RF Platform along with the EMSense interface card can be used with the HI-6000 series field probes as a field monitor in addition to its capability as a system level platform.

    For direct connection to a PC, either the HI-4413P Serial or the HI-4413USB interfaces are available.

    Specifications
    View the HI-6023 Electric Field Probe with Field-Replaceable Battery technical specifications below

    Physical Specifications

    Physical Interface: Duplex Optical Fiber (200 Micron Multimode); FSMA Connectors. Integral 1m Optical Cable
    Battery: 4.8 V NiMH, up to 8 Hours of operation
    Battery Charger: 100-240 VAC Universal Input; 3-Hour Charge from Full Depletion
    Cubical Housing Height: 32 mm (1.26 in)
    Sensor Protection Caps Height: 32 mm (1.25 in)
    Weight: 80 g (2.82 oz)
    Mounting: 1/4" 20 - UNC Internal Thread

    Electrical Specifications

    Detection: Isotropic (X, Y and Z Axis Readings)
    Frequency Range: 10 kHz to 1 GHz
    Frequency Response:
    • 10 kHz to 30 kHz +0.5, -2.5 dB
    • 30 kHz to 1 GHz 1.0 dB
    Frequency Response with Correction: 10 kHz to 1.0 GHz 0.9 dB
    Dynamic Range: 2 to 800 V/m (Single Range)
    Resolution: 0.01 V/m
    Isotropic Deviation: 0.5 dB @ 400 MHz
    Linearity: 0.5 dB (2-800 V/m)
    Sample Rate (Typical): 70 Samples/Second Maximum
    Overload Withstand: >1500 V/m CW

    Product Options

    • Optical Modem for Connection to PC Serial Port (HI-4413P)
    • Optical Modem for Connection to PC USB Port (HI-4413USB)
    • EMCenter Interface Card (125446)
    • Optical Cable Extensions to 50 m (H-491106-xx)
    • Probe Stand Assembly (H-491269)
    • Extra Probe Carriers for Above Probe Stand (H-491276)

    Product Configuration

    • HI-6023 Probe
    • A2LA Traceable Calibration Report
    • Carrying Case
    • Bulkhead Connector (2)
    • Fast Battery Charger/Battery Synchronizer
    • 10 m Optical Cable
    • Spare Screws for Battery Hatch
    • Manual

    Charts
    View the HI-6023 Electric Field Probe with Field-Replaceable Battery charts below