HI-6122 Electric Field Probe
ETS-Lindgren's Model HI-6122 EMF Field Probe is a laser-powered field probe that provides broadband EMF frequency coverage and wide dynamic range that satisfies the demands of most test requirements. To take advantage of this capability, the HI-6122 was designed to be single range reading so data can be read continuously over the entire dynamic range. Data values for each axis (X, Y, Z) can be read individually or summed.

 

 


ETS-Lindgren's Model HI-6122 EMF Field Probe is a laser-powered probe that provides broadband EMF frequency coverage and wide dynamic range that satisfies the demands of most test requirements. To take advantage of this capability, the HI-6122 was designed to be single range reading so data can be read continuously over the entire dynamic range. Data values for each axis (X, Y, Z) can be read individually or summed.​

Fiber optic signal and power lines link the Model HI-6122 field probe to either the model HI-6100 Field Monitor, or as a direct connect to a PC with the HI-6113 Laser Data Interface and ProbeView™ Laser Software.

The HI-6100 Field Monitor provides manual functions and programmed control via IEEE-488 and RS-232 Serial Data Interfaces. Readings from up to four probes can be displayed simultaneously.

The EMCenter™ Modular RF Platform along with the EMSense™ interface card can be used with the HI-6000 series field probes as a Field Monitor in addition to its capability as a system level platform.​​​​

The HI-6113 Laser Data Interface provides the laser power and communications for the HI-6122 Electric Field Probe. A USB connection to the PC allows for quick and easy data collection, using ProbeView Laser software.

Key Product Information


Specifications Select a tab below for more information



Detection: Isotropic (X, Y and Z Axis Readings)
Frequency Response with Correction: 10 kHz to 1 GHz ± 0.9 dB
Frequency Range: 10 kHz to 1 GHz
Frequency Response: 10 kHz to 30 kHz +0.5, -2.5 dB, 30 kHz to 1 GHz ± 1.0 dB
Resolution: 0.01 V/m
Isotropic Deviation: ±0.5 dB @ 400 MHz dB
Linearity: ±0.5 dB   
Sample Rate (Typical): >70 Samples per Second Maximum   
Overload Withstand: >1500 V/m CW

Physical Interface: 
  • Duplex Optical Fiber (62.5 Micron Multimode)
  • FC Connectors for Laser Cable, Integral 1m Optical Cable
  • ST Connector for Transmitter Cable, Integral 1m Optical Cable
Operating Temperature Range: 10 to 40° C (50° to 104° F), 5 to 95% Relative Humidity Non-condensing
Dimensions (Housing): 36 mm (1.42 in); 32 mm x 32 mm x 32 mm (1.26 in x 1.26 in x 1.26 in) 
Mounting: 1/4 in - 20 UNC Internal Thread
  • Manual
  • Probe Assembly
  • A2LA Traceable Calibration Report
  • 10m Optical Cable
  • Bulkhead Connector (2)
  • Carrying Case
  • Fiber Cleaning Kit and Swabs

Optical Cable Extensions (H-491263-xx)

HI-6100 Field Monitor Interface Card (H-491277)

Fiber Optic Maintenance Kit (112333)

Probe Stand (H-491269)

Extra Probe Carriers for above Probe Stand (H-491276)

EMCenter Interface Card (125428) 

​​


 

 

 

HI-6105 Electric Field Probe http://www.ets-lindgren.com/products/probes-monitors/emc-probes/electric-field-probes/9003/900304HI-6105 Electric Field Probe
HI-6006 Electric Field Probe with Field-Replaceable Battery http://www.ets-lindgren.com/products/probes-monitors/emc-probes/electric-field-probes/9003/900307HI-6006 Electric Field Probe with Field-Replaceable Battery
HI-6053 Electric Field Probe http://www.ets-lindgren.com/products/probes-monitors/emc-probes/electric-field-probes/9003/900303HI-6053 Electric Field Probe
HI-6023 Electric Field Probe with Field-Replaceable Battery http://www.ets-lindgren.com/products/probes-monitors/emc-probes/electric-field-probes/9003/900308HI-6023 Electric Field Probe with Field-Replaceable Battery
HI-6122 Electric Field Probe http://www.ets-lindgren.com/products/probes-monitors/emc-probes/electric-field-probes/9003/900305HI-6122 Electric Field Probe
HI-6153 Electric Field Probe http://www.ets-lindgren.com/products/probes-monitors/emc-probes/electric-field-probes/9003/900306HI-6153 Electric Field Probe

Key Features


  • Laser Powered - Permits Extended Testing
  • Frequency Range: 10 kHz to 1 GHz 
  • Dynamic Range 2.0 to 800 V/m (Single Range)
  • Provides Individual and Summed Axis Values 
  • A2LA Accredited Calibration Report
  • Suitable for MIL Standard Specs:
    • MIL-STD 461E Radiated Susceptibility (RS) 
  • Suitable for Automotive Specs:
    • SAE J1113/27GMW 3091/3097/3103 
  • Suitable for Commercial Specs:
    • EN/IEC61000-4-3 
  • Radiated Immunity
  • Operates with Most 3rd Party Immunity Software

Literature and Videos


 

 

http://www.ets-lindgren.com/products/probes-monitors/emc-probes/electric-field-probes/9003/900305<a href="/sites/etsauthor/ProductBrochures/General%20Brochures/Test_and_Measurement_Full_Line.pdf"><img alt="" src="/_layouts/15/IMAGES/icpdf.png" />Test_and_Measurement_Full_Line.pdf</a>

 

 

http://www.ets-lindgren.com/products/probes-monitors/emc-probes/electric-field-probes/9003/900305

L o a d i n g

 Catalog-Item Reuse