94606-1 Current Probe
ETS-Lindgren's Model 94606-1 Current Probes have a large window diameter, making this probe very versatile.

 

 


ETS-Lindgren's Model 94606-1 Current Probes have a large window diameter, making this probe very versatile. Any current conducted measurement in the frequency range 1 kHz to 100 MHz may be performed with these probes, including applications requiring the measurement of low duty cycle, high level pulsed currents. The 94606 series may be seen as a large window diameter substitute for the 91550 series (appropriate frequency range and sensitivity must be selected from the available models). The larger diameter of this series is extremely useful when making common mode measurements as per MIL-STD-1399, Section 390, or for diagnostic purposes. This common mode test requires both EUT feeder and return to be routed through the probe window.

The 12.7 cm (5 in) window makes the 94606 series probes suitable for measurements on any size power or signal cable (AWG 4/0 cable, good for several hundred amps, is 12.7 mm (0.5 in) diameter, exclusive of insulation). Probe saturation current is compatible with the current carrying capacity of wires placed in its window. (Some of the models have lower saturation limits with 400 Hz power.)

Key Product Information


Specifications Select a tab below for more information



Frequency Minimum: 10 kHz
Frequency Maximum: 100 MHz
Load Impedance: 50 +/- j0
Maximum Primary Current Amps:
  • 400 Hz: 350
  • DC-60 Hz: 350
  • Pulse: 100
  • RF(CW) : 100
Transfer Impedance: 5 Ω
Outside Diameter: 19.81 cm (7.80 in)
Width: 5.38 cm (2.12 in)
Window Diameter: 12.7 cm (5.00 in)
Weight: 3.18 kg (7.01 lb)
​​

 

 

91550-1 Current Probe http://www.ets-lindgren.com/products/probes-monitors/emc-probes/current-probes/9006/90060291550-1 Current Probe
91550-2 Current Probe http://www.ets-lindgren.com/products/probes-monitors/emc-probes/current-probes/9006/90060391550-2 Current Probe
93686-8 Current Probehttp://www.ets-lindgren.com/products/probes-monitors/emc-probes/current-probes/9006/90060793686-8 Current Probe
94430-1 Current Probe http://www.ets-lindgren.com/products/probes-monitors/emc-probes/current-probes/9006/90061094430-1 Current Probe
93511-1 Current Probe http://www.ets-lindgren.com/products/probes-monitors/emc-probes/current-probes/9006/90060593511-1 Current Probe
94606-1 Current Probe http://www.ets-lindgren.com/products/probes-monitors/emc-probes/current-probes/9006/90061194606-1 Current Probe
91550-5 Current Probe http://www.ets-lindgren.com/products/probes-monitors/emc-probes/current-probes/9006/90060491550-5 Current Probe
94106-1 Current Probe http://www.ets-lindgren.com/products/probes-monitors/emc-probes/current-probes/9006/90060894106-1 Current Probe
94111-1 Current Probe http://www.ets-lindgren.com/products/probes-monitors/emc-probes/current-probes/9006/90060994111-1 Current Probe
91197-1 Current Probe http://www.ets-lindgren.com/products/probes-monitors/emc-probes/current-probes/9006/90060191197-1 Current Probe
94606-6 Current Probe http://www.ets-lindgren.com/products/probes-monitors/emc-probes/current-probes/9006/90061294606-6 Current Probe
93686-1 Current Probe http://www.ets-lindgren.com/products/probes-monitors/emc-probes/current-probes/9006/90060693686-1 Current Probe

Key Features


  • For Standards Testing and Pre-compliance Applications 
  • Measures RF Current Without Direct Connection