94111-1 Current Probe
ETS-Lindgren's Model 94111-1 Current Probe is capable of making bulk current injection measurements up to 1 GHz.

 

 


​ETS-Lindgren's Model 94111-1 Current Probe is capable of making bulk current injection measurements up to 1 GHz. The 94111-1 is a diagnostic tool for cable common mode current sources of radiated emissions and as measurement of cable common mode coupled currents during radiated susceptibility testing.

The 3.18 cm (1.25 in) window makes the 94111 series probes suitable for measurements on most power cables (AWG 4/0 cable, good for several hundred amps, is 12.7 mm (0.5 in) diameter, exclusive of insulation). Probe saturation current is compatible with the current carrying capacity of wires placed in its window.

Key Product Information


Specifications Select a tab below for more information



Frequency Minimum: 1 MHz
Frequency Maximum: 1000 MHz
Load Impedance: 50 +/- j0
Maximum Primary Current Amps:
  • 400 Hz: 200
  • DC-60 Hz: 200
  • Pulse: 50
  • RF(CW): 20
Transfer Impedance: 1 to 10 Ω    
Outside Diameter: 8.26 cm (3.25 in)
Window Diameter: 3.18 cm (1.25 in)
Width: 3.56 cm (1.40 in)
Weight: 0.43 kg (0.95 lb )
 

 

 

91550-1 Current Probe http://www.ets-lindgren.com/products/probes-monitors/emc-probes/current-probes/9006/90060291550-1 Current Probe
93686-8 Current Probehttp://www.ets-lindgren.com/products/probes-monitors/emc-probes/current-probes/9006/90060793686-8 Current Probe
93511-1 Current Probe http://www.ets-lindgren.com/products/probes-monitors/emc-probes/current-probes/9006/90060593511-1 Current Probe
94430-1 Current Probe http://www.ets-lindgren.com/products/probes-monitors/emc-probes/current-probes/9006/90061094430-1 Current Probe
91550-2 Current Probe http://www.ets-lindgren.com/products/probes-monitors/emc-probes/current-probes/9006/90060391550-2 Current Probe
94111-1 Current Probe http://www.ets-lindgren.com/products/probes-monitors/emc-probes/current-probes/9006/90060994111-1 Current Probe
94606-1 Current Probe http://www.ets-lindgren.com/products/probes-monitors/emc-probes/current-probes/9006/90061194606-1 Current Probe
94106-1 Current Probe http://www.ets-lindgren.com/products/probes-monitors/emc-probes/current-probes/9006/90060894106-1 Current Probe
91550-5 Current Probe http://www.ets-lindgren.com/products/probes-monitors/emc-probes/current-probes/9006/90060491550-5 Current Probe
91197-1 Current Probe http://www.ets-lindgren.com/products/probes-monitors/emc-probes/current-probes/9006/90060191197-1 Current Probe
94606-6 Current Probe http://www.ets-lindgren.com/products/probes-monitors/emc-probes/current-probes/9006/90061294606-6 Current Probe
93686-1 Current Probe http://www.ets-lindgren.com/products/probes-monitors/emc-probes/current-probes/9006/90060693686-1 Current Probe

Key Features


  • For Standards Testing and Pre-compliance Applications 
  • Measures RF Current Without Direct Connection

Literature and Videos


 

 

http://www.ets-lindgren.com/products/probes-monitors/emc-probes/current-probes/9006/900609<a href="/sites/etsauthor/ProductBrochures/General%20Brochures/Test_and_Measurement_Full_Line.pdf"><img alt="" src="/_layouts/15/IMAGES/icpdf.png" />Test_and_Measurement_Full_Line.pdf</a>

 

 

http://www.ets-lindgren.com/products/probes-monitors/emc-probes/current-probes/9006/900609

L o a d i n g

 Catalog-Item Reuse