EMGen RF Signal Generator Model 7003-003

EMGen 7003-003

ETS-Lindgrens EMGenTM RF Signal Generator Plug-in Card offers users a convenient and economical solution for signal generation.

ETS-Lindgrens EMGen RF Signal Generator offers users a convenient and economical solution for signal generation. The EMGen Module is designed to fit into the EMCenter Modular Test System and provides the user with a signal generator that can be used in different modes across the 4 kHz to 6 GHz frequency range.

Key Features
  • Easy to Use
  • Accurate Measurements for EMC Test
Product Details
Product Features

Flexible Operation

The EMGen EMC Signal Generator can be used in Continuous Wave (CW) mode, as well as AM, FM or pulse modulation mode.
The EMGen covers a frequency range from 4 kHz to 6 GHz and can be used for both conducted and radiated immunity tests. It has a single SMA output connector.

Accurate Measurements

The EMGen is an accurate RF signal generator with a frequency error of +/- 1ppm/Year and a modulation accuracy of 1 Hz/< 1%. At the same time its output has an extremely fast response (less than 500s) which is very important for EMC testing.
In addition, special engineering efforts have been taken to assure complete monotone behavior and prevent undesirable results at the output level. All these features make the EMGen the perfect signal generator for EMC immunity testing.

Easy to Use

The EMGen system is Plug-and-Play, meaning this card is automatically recognized and initialized by the EMCenter and is immediately ready to use. The user can configure and control the system by using TILE! Lab Management Software.

Physical Specifications
Dimensions: 3U x One 19 in Slot in EMCenter
Temperature Range (Use): +10 C to +40 C
Relative Humidity: 10 to 90% (Non-condensing)
Electrical Specifications
Model
7003-003 Plug-in Card Feature
Frequency Band
4 kHz to 6 GHz
Frequency Resolution
1 Hz
Frequency Error
+/- 1 ppm per year
Minimum Output Level
-70 dBm
Maximum Output Level
+13 dBm (+7.0 dBm When Using AM)
Amplitude Resolution
0,1 dBm
Amplitude Accuracy
+/- 1 dB +/- 0,01 dB/dB
Output Level Settling Time
< 1 msec
Harmonics
<- 20 dBc
Non-Harmonic Spurious
<- 50 dBc
Modulation Types
CW, AM, FM, Pulse and Gated Pulse
Modulation Frequency Range
1 Hz to 100 kHz
AM Modulation Depth
5 to 95% (Usable 0 to 100%)
AM Accuracy, Output LF
Measured at 0 dBm Level
< +/- 3% (5 to 95% Modulation Depth)
AM Accuracy, Output HF
Measured at 0 dBm Level
< +/- 2% (10% to 90% Modulation Depth)
< +/- 3% (5 to 10% and 90 to 95% Modulation Depth)
Pulse On/Off Time Range
200 ns to 100 s
Pulse Modulation On/Off Ratio
Output
> 90 dB
Supply
12/28 VDC