Key Product Information


Specifications Select a tab below for more information



Feed Connector Type: cw 7/16 DIN to N Adapter
Field Uniformity: f 1 GHz, 0 -6dB
Frequency: 9 kHz to 5 GHz (RE)1; DC - 20 GHz (RI)2
Input Impedance: 50 Ω
Maximum CW Input: 1 kW
Shielding Effectiveness: 10 kHz to 1 GHz From Internal E-Fields 80 dB Minimum
VSWR Maximum: All Other Frequencies 1.50:1; Characteristic Frequencies 1.75:1
VSWR Typical: All Other Frequencies 1.30:1; Characteristic Frequencies3 1.75:1

1Measurement Range - where correlation to OATS is established: 
3 Measurement - 3 input GTEM-OATS Correlation Algorithm, 30 MHz to 5 GHz
9 Measurement - 9 input GTEM -OATS Correlation Algorithm, 9 kHz to 5 GHz
2Low input VSWR to f</= 20 GHz available
3Characteristic Frequency: The frequency at which cross-over between the two terminations (the resistor load boards and the RF absorber) occurs.
Door Dimension Primary Height: 685.0 mm (26.97 in)
Door Dimension Primary Width: 925.0 mm (36.42 in)
Maximum Septum Height:4 1100.0 mm (43.31 in)
Highest Accuracy Transverse Test Surface in Center of Cell Height:5 366.0 mm (14.41 in)
Highest Accuracy Transverse Test Surface in Center of Cell Width:5 550.0 mm (21.65 in)
Maximum Recommended Transverse Test Surface in Center of Cell Height:6 733.0 mm (28.86 in)
Maximum Recommended Transverse Test Surface in Center of Cell Width:6 825.0 mm (32.48 in)
Outer Cell w/Base Dimension Height: 2.3 m (7.55 ft)
Outer Cell w/Base Dimension Length: 5.4 m (17.72 ft)
Outer Cell w/Base Dimension Width: 2.8 m (9.19 ft)
Approximately Cell Weight: 900.0 kg (1,984.14 lb)
Distributed Load Rating: 750 kg (1,653.45 lb)

4Measurement taken at rear of test volume.
5From quasi-static E-Field with H=1/3 septum height and W=1/3 septum width.
6From quasi-static E-Field with H=2/3 septum height and W=2/3 septum width.
  • Absorber-lined GTEM! Test Cell
  • Mobile Base with Locking Casters
  • Blank feed-thru Panel without Frame
  • Removable Bolt-on Feed Section
  • Primary Door 68.6 cm x 92.5 cm (27 in x 36.42 in) Clear Opening
  • Two AC Receptacles
  • Forced Air Ventilation
  • One Fiber Optic Penetration
  • One 20 AMP, 2 Line Filter
  • Additional Maintenance Kit
  • Three N-type Connectors
  • 7/16" DIN to Type "N" Adapter
  • Shipped Disassembled (Customer to Provide Manpower and Tools for Assembly)
  • Working supervisor for installation is provided; outside North America, call factory,
  • Air Compressor for Manipulator Brake System
  • Manual Emissions Correlation Software (on Request)
  • Individually Characterized with Results of TDR and VSWR Tests
  • Manual



 

 

5405 GTEM! Test Cellhttp://www.ets-lindgren.com/products/tem-devices/gtem-test-cells/13001/13001025405 GTEM! Test Cell
5411 GTEM! Test Cell Config http://www.ets-lindgren.com/products/tem-devices/gtem-test-cells/13001/13001045411 GTEM! Test Cell Config
5402 GTEM! Test Cell http://www.ets-lindgren.com/products/tem-devices/gtem-test-cells/13001/13001015402 GTEM! Test Cell
5407 GTEM! Test Cell http://www.ets-lindgren.com/products/tem-devices/gtem-test-cells/13001/13001035407 GTEM! Test Cell
5502 Horizontal/Vertical (H/V) Electric Field Generator http://www.ets-lindgren.com/products/tem-devices/horizontal-vertical-(h-v)-electric-field-generator/13001/13002015502 Horizontal/Vertical (H/V) Electric Field Generator

Key Features


  • For all Phases of EMC Testing:
    • Design Qualification
    • Pre-Compliance
    • Full Compliance IEC 61000-4-3 ANSI C63.4 
    • Post Production

Literature and Videos


 

 

http://www.ets-lindgren.com/products/tem-devices/gtem-test-cells/13001/1300104<a href="/sites/etsauthor/ProductBrochures/General%20Brochures/Test_and_Measurement_Full_Line.pdf"><img alt="" src="/_layouts/15/IMAGES/icpdf.png" />Test_and_Measurement_Full_Line.pdf</a>

 

 

http://www.ets-lindgren.com/products/tem-devices/gtem-test-cells/13001/1300104

L o a d i n g

 Catalog-Item Reuse