Key Product Information


I/O Connector Panels

Multiple preconfigured I/O panel options are available.  As these panels are conveniently interchangeable in the field, users can update their existing 5600 test box to meet new testing requirements. Ethernet (POE) and USB 2.0 filter offerings are designed to maintain signal integrity and minimize electromagnetic interference from entering in or leaking out from the enclosure. DC power option is available using DB9 (5A max) or with terminal style (20A max) filtered connectors. 

Microwave Absorber 

ETS-Lindgren lossy foam moderate performance RF absorber (constructed of a graded dielectric material) provides absorption at microwave frequencies, thus eliminating unwanted reflection within the RF enclosure. 

Dual Layer Sealed Door

5600 series test boxes have a precision installed "braid over foam" RF seal on the enclosure's integrated lip channel. This works to resist compression sets to more than 50,000 cycles and extends the lifespan of the RF seal performance.

Durable Construction  

Consistent to all ETS-Lindgren product lines, the 5600 series offers lightweight and robust construction, versatile for any wireless testing need. 

  • Dual layer reinforced door cover and durable hinges with stoppers that prevent bending and warping of the top side geometry (most susceptible area of an RF enclosure)

  • High quality nickel fabric over urethane foam core dual gasket door seals

  • All metal is conversion coated to maintain conductivity prior to powder coating to minimize oxidation.

 

Specifications Select a tab below for more information



​Frequency Range

​Typical RF Isolation

​300 MHz to 3 GHz

​80 dB

​3 GHz to 6 GHz

​80 dB

​6 GHz to 13 GHz

​70 dB

​Standard Model Number

​Dimensions

​5601 (Tabletop)

30.48 cm L x 45.72 cm W x 20.32 cm H (12 in x 18 in x 8 in)​

​5602 (Tabletop)

​45.72 cm L x 60.96 cm W x 30.48 cm H (18 in x 24 in x 12 in)

​5604 (9U Rack Mount)

​53.34 cm D x 43.18 cm W x 38.1 cm H (21 in x 17 in x 15 in)

Note: The 9U Rack Mount box includes passive air ventilation with an externally mounted 110 VAC exhaust fan with power cord.  

 

5601 (Tabletop)

12"W x 18"L x 8"H

5602 (Tabletop)

18"W x 24"L x 12"H

5604 (9U Rack Mount)

21"D x 17"W x 15"H

Panel - A

​2 ea SMA

1 ea DB9​ D-Sub

​2 ea SMA

1 ea DB9​ D-Sub

​​2 ea SMA

1 ea DB9​ D-Sub

Panel - B

2 ea SMA Connectors
1 ea DB9 D-Sub
1 ea USB 2.0
1 ea Ethernet

2 ea SMA Connectors
1 ea DB9 D-Sub
1 ea USB 2.0
1 ea Ethernet

2 ea SMA Connectors
1 ea DB9 D-Sub
1 ea USB 2.0
1 ea Ethernet

Panel - C

2 ea SMA Connectors
1 ea DB9 D-Sub
1 ea USB 2.0
1 ea Ethernet
1 ea DC Power

2 ea SMA Connectors
1 ea DB9 D-Sub
1 ea USB 2.0
1 ea Ethernet
1 ea DC Power

2 ea SMA Connectors
1 ea DB9 D-Sub
1 ea USB 2.0
1 ea Ethernet
1 ea DC Power

Panel - D

​2 ea SMA Connectors
1 ea DB9 D-Sub
1 ea USB 2.0
1 ea Ethernet
1 ea AC Power Interface

2 ea SMA Connectors
1 ea DB9 D-Sub
1 ea USB 2.0
1 ea Ethernet
1 ea AC Power Interface

2 ea SMA Connectors
1 ea DB9 D-Sub
1 ea USB 2.0
1 ea Ethernet
1 ea AC Power Interface

Panel - E

​8 ea SMA Connectors
2 ea N
1 ea USB 2.0
1 ea Ethernet
1 ea AC Power Interface

​​8 ea SMA Connectors
2 ea N
1 ea USB 2.0
1 ea Ethernet
1 ea AC Power Interface

​​8 ea SMA Connectors
2 ea N
1 ea USB 2.0
1 ea Ethernet
1 ea AC Power Interface

 

 NOTE:  Although I/O panels are interchangeable, only one (1) I/O panel may be mounted to a box at one time. Please contact your ETS-Lindgren representative for custom configurations.

​Pre-Configured Test Box Models:

 

5601 (Tabletop)

12"W x 18"L x 8"H

5602 (Tabletop)

18"W x 24"L x 12"H

5604 (9U Rack Mount)

21"D x 17"W x 15"H

Panel - A

​2 ea SMA

1 ea DB9​ D-Sub

​2 ea SMA

1 ea DB9​ D-Sub

​​2 ea SMA

1 ea DB9​ D-Sub

Panel - B

2 ea SMA Connectors
1 ea DB9 D-Sub
1 ea USB 2.0
1 ea Ethernet

2 ea SMA Connectors
1 ea DB9 D-Sub
1 ea USB 2.0
1 ea Ethernet

2 ea SMA Connectors
1 ea DB9 D-Sub
1 ea USB 2.0
1 ea Ethernet

Panel - C

2 ea SMA Connectors
1 ea DB9 D-Sub
1 ea USB 2.0
1 ea Ethernet
1 ea DC Power

2 ea SMA Connectors
1 ea DB9 D-Sub
1 ea USB 2.0
1 ea Ethernet
1 ea DC Power

2 ea SMA Connectors
1 ea DB9 D-Sub
1 ea USB 2.0
1 ea Ethernet
1 ea DC Power

Panel - D

​2 ea SMA Connectors
1 ea DB9 D-Sub
1 ea USB 2.0
1 ea Ethernet
1 ea AC Power Interface

2 ea SMA Connectors
1 ea DB9 D-Sub
1 ea USB 2.0
1 ea Ethernet
1 ea AC Power Interface

2 ea SMA Connectors
1 ea DB9 D-Sub
1 ea USB 2.0
1 ea Ethernet
1 ea AC Power Interface

Panel - E

​8 ea SMA Connectors
2 ea N
1 ea USB 2.0
1 ea Ethernet
1 ea AC Power Interface

​​8 ea SMA Connectors
2 ea N
1 ea USB 2.0
1 ea Ethernet
1 ea AC Power Interface

​​8 ea SMA Connectors
2 ea N
1 ea USB 2.0
1 ea Ethernet
1 ea AC Power Interface

 

I/O Connector Panel Options: 

Panel A - 1634573

​Panel B - 1634574

​Panel C - 1634575

Panel D - 1634576

Panel E - 1634577

2 ea SMA Connectors

1 ea DB9​ D-Sub

​2 ea SMA Connectors

1 ea DB9 D-Sub

1 ea USB 2.0

1 ea Ethernet

2 ea SMA Connectors
1 ea DB9 D-Sub
1 ea USB 2.0

1 ea Ethernet

1 ea DC Power

2 ea SMA Connectors

1 ea DB9 D-Sub

1 ea USB 2.0

1 ea Ethernet

1 ea AC Power Interface

8 ea SMA Connectors

2 ea N

1 ea USB 2.0

1 ea Ethernet

1 ea AC Power Interface

NOTE:  Although I/O panels are interchangeable, only one (1) I/O panel may be mounted to a box at one time. Please contact your ETS-Lindgren representative for custom configurations.

 

 

5201 Tabletop RF Test Enclosure ​​​ETS-Lindgren's Model 5201 Tabletop RF Test Enclosure is a self-contained, portable test cell designed for testing wireless devices in a development, production, and/or quality assurance environment.
5211 Wireless Interface Test System ETS-Lindgren's Model 5211 Wireless Interface Test System, (WITS™), is a self-contained portable enclosure that can check cell phone transmit and receive functionality with or without direct cable connection to the RF or data ports.
5225-2 Access Point Test Enclosure ETS-Lindgren's Model 5225-2 Bench-Top Test System has been developed for testing medium-sized wireless devices, such as laptop computers.
5230 Table Top Test Enclosure <p>​ETS-Lindgren's 5230 Table Top RF Test Enclosures are upright,  bench top test cells for testing larger sized DUTs.</p>
5240 Table Top Test Enclosures <span class="ms-rteThemeForeColor-2-0"></span>​ETS-Lindgren's Series 5240 RF-Shielded Tabletop Test Enclosures are high performance, portable shielded enclosures designed for fast, convenient EMI/RFI testing and repair.​​
5247 Shielded Test Cell Enclosure ETS-Lindgren's Model 5247 Shielded RF Test Enclosure is a self-contained portable enclosure for making wireless device over the-air performance measurements.
5600 Series Test Box <p>ETS-Lindgren's 5600 series of RF Test Enclosures are self-contained, portable test cell enclosures designed for testing wireless devices in a development, production, and/or quality assurance environment, from 300 MHz to 13 GHz.<br></p>
SMART 800 Mini-Reverb Cell SMART™800* Mini-Reverb Cell is a bench-top version of our larger room-sized reverberation chambers.<br><div> * The number refers to the lowest operating frequency and for measurements made to the RTCA DO160F/G Standard the operation of the cell can be extended to 800 MHz.<br></div>

Key Features


  • Frequency Range: 300 MHz to 13 GHz
  • 80 dB+ of Isolation Shielding Effectiveness Over Frequency Spectrum
    • Planewave at 300 MHz to 2 GHz:  80 dB
    • Planewave at 2 GHz to 6 GHz:       80 dB
    • Planewave at 6 GHz to 13 GHz:     70 dB
  • Quick Availability
  • Lightweight Tabletop or 19" Rack Mount Available
  • Dual Layer Sealed Door with High Performance Braid Over Foam RF Seal with Dual Paddle Latches
  • Interchangeable I/O Connector Panels

Literature and Videos


 

 

http://www.ets-lindgren.com/products/test-enclosures/14000/1400009<a href="/sites/etsauthor/ProductBrochures/General%20Brochures/Test_and_Measurement_Full_Line.pdf"><img alt="" src="/_layouts/15/IMAGES/icpdf.png" />Test_and_Measurement_Full_Line.pdf</a>

 

 

http://www.ets-lindgren.com/products/test-enclosures/14000/1400009

L o a d i n g

 Catalog-Item Reuse