Key Product Information


Specifications Select a tab below for more information



Feed Connector Type: cw 7/16 DIN to N Adapter
Field Uniformity: f <1 GHz; 0 -6dB
Frequency: 9 kHz to 5 GHz (RE)1; DC - 20 GHz (RI)2
Input Impedance: 50 Ω
Maximum CW Input: 50 W
Shielding Effectiveness: 10 kHz to 1 GHz From Internal E-Fields 80 dB Minimum
VSWR Maximum: All Other Frequencies <1.50:1; Characteristic Frequencies <1.75:1
VSWR Typical: All Other Frequencies 1.30:1; Characteristic Frequencies3 1.75:1

1Measurement Range: Where correlation to OATS is established3 Measurement - 3 input GTEM to OATS Correlation Algorithm, 30 MHz - 5 GHz; 9 Measurement - 9 input GTEM to OATS Correlation Algorithm, 9 kHz - 5 GHz
2Low Input VSWR to f</= 20 GHz Available
3Characteristic Frequency: The frequency at which cross-over between the two terminations (the resistor load boards and the RF absorber) occurs.
Distributed Load Rating: 100 mm (3.94 in)
Door Dimension Primary Height: 160.0 mm (6.30 in)
Door Dimension Primary Width: 230.0 mm (9.06 in)
Door Dimension Secondary Height: 100 mm (3.94 in)
Door Dimension Secondary Width: 100 mm (3.94 in)
Outer Cell w/Base Dimension Height: 0.5 m (1.64 ft)
Outer Cell w/Base Dimension Length: 1.4 m (4.59 ft)
Outer Cell w/Base Dimension Width: 0.75 m (2.46 ft)
Maximum Septum Height4: 250.0 mm (9.84 in)
Highest Accuracy Transverse Test Surface in Center of Cell Height5: 83.0 mm (3.27 in)
Highest Accuracy Transverse Test Surface in Center of Cell Width5: 125.0 mm (4.92 in)
Maximum Recommended Transverse Test Surface in Center of Cell Height6: 125.0 mm (4.92 in)
Maximum Recommended Transverse Test Surface in Center of Cell Height6: 167.0 mm (6.57 in)
Approximate Cell Weight: 40.0 kg (88.18 lb)

4Measurement taken at rear of test volume.
5From quasi-static E-Field with H=1/3 septum height and W=1/3 septum width.
6From quasi-static E-Field with H=2/3 septum height and W=2/3 septum width.
  • Absorber-lined GTEM!
  • One Removable Access Port in Floor
  • Primary Door; 16 cm x 23 cm (6.3 in x 9.1 in) W x H Clear Opening
  • Manual Emissions Correlation Software (on Request)
  • 7/16" DIN to Type N Adapter
  • Individually Characterized with Results of TDR and VSWR Tests
  • Completely Assembled
  • Manual

  •  

     

    5402 GTEM! Test Cell ​ETS-Lindgren's Model 5402 GTEM!™ Test Cell enables users to perform radiated emissions and radiated immunity tests in less time than at either an OATS or in a chamber.
    5405 GTEM! Test Cell​ETS-Lindgren's Model 5405 GTEM!™ Test Cell enables users to perform radiated emissions and radiated immunity tests in less time than either an OATS or in a chamber. 
    5407 GTEM! Test Cell ​ETS-Lindgren's Model 5407 GTEM!™ Test Cell enables users to perform radiated emissions and radiated immunity tests in less time than at either an OATS or in a chamber. <br>
    5411 GTEM! Test Cell ​ETS-Lindgren's Model 5411 GTEM!™ Test Cell enables users to perform radiated emissions and radiated immunity tests in less time than either an OATS or a chamber.
    5502 Horizontal/Vertical (H/V) Electric Field Generator <p>​ETS-Lindgren’s 5502 Horizontal/ Vertical (H/V) Electric Field Generator is a two conductor transmission line system that generates a Transverse Electromagnetic wave (TEM) to support Immunity testing of a device positioned below the conductors.<br></p>

    Key Features


    • For all Phases of EMC Testing:
      • Design Qualification
      • Pre-Compliance
      • Full Compliance IEC 61000-4-3 ANSI C63.4