Key Product Information


Versatile Smaller Format

The LMF-4112 is a versatile filter that is utilized for standard lighting, switching and power circuits. This filter offers the advantage of an approximately 50% reduction in required surface area and weight. This means the use of more circuits with substantially less space and weight than standard filters offering the same features. This filter has a 0 - 30 amp rating and operates at 250 VAC/VDC. It is c-UL rated and CE marked. The EQ series are used for conventional thermostats, nurse calls, fire alarms, smoke detectors or any low leakage application requiring measurement of small variances in voltage to perform an application. This series of filters has an operating range of 1 to 10 amps and 24 VAC/VDC. It is also c-UL rated and CE marked. The ELUL filters are utilized for standard lighting, switching and power circuits. They are able to run at higher voltage requirements with a 0 - 30 amp range and operating up to 277 VAC and 480 VDC. It is c-UL rated and CE marked. 

 

Applications

ELUL, LMF and EQ filters are utilized to allow electrical services within a Magnetic Resonance Imaging suite. All applications that require a conductor within the room interface with a filter. The most common services are lighting, power, smoke detectors and fire alarms.


           
           
             

 

Specifications Select a tab below for more information



​Model
ELUL-2030 
(Power, Light)​
EQ-2001-NR
(Smoke, Fire, Thermo.)​
EQ-2010-1C
(ERDU, EPO)​
LMF-3519
(CCTV)​
​Part Number
E-ELUL-2030​
​E-EQ-2001-NR
​E-EQ-2010-1C
​E-LMF-3519
​Rated Current (Amps)
0 to 30​0 to 1.0​0 to 10​0 to 10​
Max. Leakage Current
@220 V, 50 Hz
700 mA3 mA3 mA
N/A
Max. Leakage Current
@120 V, 60 Hz
450 mA1.5 mA
1.5 mAN/A
Rated Voltage0-277/480 VAC/VDC0-30/50 VAC/VDC0-250/250 VAC/VDC0-24 VDC
Insertion Loss100 dB min. from 150 kHz to 10 GHz per MIL-STD-220A.100 dB min. from 150 kHz to 18 GHz per MIL-STD-220A.100 dB min. from 150 kHz to 18 GHz per MIL-STD-220A.100 dB min from 30 MHz - 10 GHz per MIL-STD-220A
Voltage DropNot to exceed 1% of applied voltage at Unity Power Factor.Not to exceed 1% of applied voltage at Unity Power Factor.Not to exceed 1% of applied voltage at Unity Power Factor.N/A
SafetyDischarge resistors provided per UL-1283.Discharge resistors provided per UL-1283.Discharge resistors provided per UL-1283.N/A
Passband ImpedanceN/AN/AN/A75 (L-G)

​Model
ELUL-2030 
(Power, Light)​
EQ-2001-NR
(Smoke, Fire, Thermo.)​
EQ-2010-1C
(ERDU, EPO)​
LMF-3519
(CCTV)​
​Part Number
E-ELUL-2030​
​​E-EQ-2001-NR
​E-EQ-2010-1C
​​E-LMF-3519
Number of Lines
2
2
2
1​
Weight
6.8 kg (15.0 lb)
2.7 kg (6.0 lb)
2.7 kg (6.0 lb)

2.7 kg (6.0 lb)

Dimension A
53.98 cm (21.25 in) 38.74 cm (15.25 in)
38.74 cm (15.25 in) 38.74 cm (15.25 in)
Dimension B 52.71 cm (20.75 in) 37.47 cm (14.75 in)
37.47 cm (14.75 in)
37.47 cm (14.75 in)
Dimension C 50.8 cm (20.0 in) 35.56 cm (14.0 in) 35.56 cm (14.0 in) 35.56 cm (14.0 in)
Dimension D 12.7 cm (5.0 in) 7.62 cm (3.0 in). 7.62 cm (3.0 in) 7.62 cm (3.0 in)
Dimension E 7.62 cm (3.0 in) 5.08 cm (2.0 in) 5.08 cm (2.0 in)
5.08 cm (2.0 in)
Dimension F 3.96 cm (1.56 in) 3.81 cm (1.5 in) 3.81 cm (1.5 in) 3.81 cm (1.5 in)


​Dimension G
​7.62 cm (3.0 in)
​5.08 cm (2.0 in)
​5.08 cm (2.0 in)
​5.08 cm (2.0 in)

  • Mounting Tabs Provide Secure Access
  • Feedthrough Penetration Pipe for Electrical Leads Functions as a Frequency Waveguide Cut-off
  • Single Phase, Two Line Filters
  • Seam Welded Case with Removable RF Gasketed Lid, Tin Coated for Long Wear

 

 

Automatic Opener/Closer For use with Auto-Seal II Door<p>ETS-Lindgren's Automatic Door Opener/Closer (AOC) provides easy access into the MRI with adjustable timing on the opening and closing operation.</p>
CCTV Intercom System ​ETS-Lindgren's CCTV Intercom System is a reliable and efficient method for constant contact between the MRI room and the control room.
EMI/RFI Shielded Waveguide Air Vents ​​​​ETS-Lindgren's Waveguide Air Vents are manufactured to meet a variety of customer requirements. 
Magnetic Active Compensation System (MACS/D™) for MRI ETS-Lindgren's wideband digital Magnetic Active Compensation System (MACS/D™) is a triaxial magnetic field compensator designed to significantly attenuate environmental magnetic fields affecting the image quality of supercon and resistive magnet MRIs and NMRs.
Med-Vizion Graphic Display Panel (GDP) System ​​ETS-Lindgren's Med-Vizion™ LED Graphic Panel MRI Lighting System (Wall) is an advanced lighting technology designed for MRI suite applications.
Med-Vizion LED Down Light ZXR-3500 and ZXR-4000 ​ETS-Lindgren's Med-Vizion™ ZXR Down Light is the latest in lighting technology specially designed for MRI suite applications. It produces the equivalent of a 175 watt incandescent light using only 32 watts of power.
Med-Vizion™ MRI Lighting LED Sheet Lamp Recessed Troffer LFP2x2-40KETS-Lindgren's Med-Vizion™ LFP2x2-40K is a an excellent lighting solution for MRI rooms and other similar applications.
Med-Vizion™ MRI Lighting LED Sheet Lamp Recessed Troffer LFP2x4-40K <p>ETS-Lindgren's Med-Vizion™ Model LFP2x4-40K is a an excellent lighting solution for MRI rooms and other similar applications. </p>
Medical RF Filters ​ETS-Lindgren's Medical RF Filters enable electrical power, lighting and data signals to be brought into the MRI room, through the RF shield. All RF filters are typically located in one area, usually near the penetration panel of the MRI equipment.
OMS™ Sample Draw Oxygen Monitoring System ​​ETS-Lindgren’s Oxygen Monitoring System (OMS) is a sample draw monitoring system that alerts and alarms when oxygen levels fall below safe limits for human health.
SAFESCAN® Ferromagnetic Target Scanner™ ETS-Lindgren's SAFESCAN® Target Scanners are specifically designed for MR safety, and alarm only on detection of ferromagnetic threats.
Safe IV Port for Medical Applications <span class="ms-rteThemeFontFace-1"></span>ETS-Lindgren's Safe IV Port (SIVP) is a cylindrical waveguide that provides safe and easy passage of intravenous (IV) lines into an MRI room, without compromising the RF shield.
SafeScan® Ferromagnetic Detection Systems ETS-Lindgren's SAFESCAN® Single and Dual Pillar Systems offer continuous 'walk by' ferromagnetic detection for hallways or doorways.

Key Features


  • Filter Models to Match Requirements for:
    • Power and Lighting
    • Low Leakage
  • 100dB Insertion Loss from 40 kHz
  • Voltage Drop Less than 1% of Applied Voltage
  • Compliant with:
    • Low Voltage Directive 2006/95/EC
    • MIL-STD-220C
  • UL 1283 Listed, 5th Edition

Literature and Videos


 

 

http://www.ets-lindgren.com/products/shielding/medical-shielding/medical-shielding-accessories/11008/1100813<a href="/sites/etsauthor/ProductBrochures/General%20Brochures/MRI%20Full%20Line%20Brochure.pdf"><img alt="" src="/_layouts/15/IMAGES/icpdf.png" />MRI Full Line Brochure.pdf</a>

 

 

http://www.ets-lindgren.com/products/shielding/medical-shielding/medical-shielding-accessories/11008/1100813

L o a d i n g

 Catalog-Item Reuse