SafeScan® Ferromagnetic Detection Systems
ETS-Lindgren's SAFESCAN® Single and Dual Pillar Systems offer continuous 'walk by' ferromagnetic detection for hallways or doorways.

 

 


​ETS-Lindgren's SAFESCAN Single and Dual Pillar Systems offer continuous 'walk by' ferromagnetic detection for hallways or doorways. ​​​SAFESCAN Systems are designed to be located on either side of a door. The door can be left or right handed, in- or out-swing.​​ 

The SAFESCAN Dual Pillar FMDS (FMDS-100) is the ideal solution for 24 hour, ferromagnetic detection. Designed to bracket a doorway or hallway with a pillar on each side, the Dual Pillar FMDS is equipped with the industry’s highest sensitivity settings. Working with our Safety Experts, we will help you select the best positioning, sensitivity settings and whether warning lights, audible alarm or both is suitable for your situation. With easy-to-operate controls, the Dual Pillar System provides the highest degree of ferrous detection for a ‘walk by’ Ferrous Detection System. We will work closely with you to determine the options that best fit your procedures and facility, along with providing installation and staff training to insure effectiveness of the FMDS. ​

When you are unable to physically place a detection pillar on both sides of a hallway or doorway, the SAFESCAN Single Pillar FMDS (FMDS-300) is the solution for you. Constantly on and sensing for ferrous objects, your MRI suite is being protected 24 hours a day. A SAFESCAN Dual Pillar system is always recommended over a SAFESCAN Single Pillar in order to capture a larger sensing area; however what is desired and what is physically possible don’t always coincide. 

Key Product Information


Specifications Select a tab below for more information



Model
Power​Safety Listings​
​FMDS-100
FMDS-300
​​100/240 VAC, 50/60 Hz, 0.06 A Maximum,
0.03 A Nominal 
​UL Listed E210311, CE Mark

Model​
Pillar Spacing
Control:
Day/Night Mode ​
​Control: Volume
Control: Sensitivity​Visual Indicator: Green Light​Visual Indicator: Red Light​Audio Indicator: Buzzer Off​Audio Indicator: Buzzer On​Circuit Activation​Alarm Management​
​FMDS-100
66 cm to 137 cm (26 in to 54 in)​​Rocker Switch
​Variable Rotary Knob
​Multi-position Rotary Switch with Key, Lock ​Visual Indicators​
​Continue; Ferromagnetic ​Item Not Detected
​Stop; Ferromagnetic Item Detected
​Detection Threshold Not Exceeded
​Stop, Ferromagnetic Item Detected
(Two-tone, Nominal 2.5 kHz to 3.8 kHz Audio Frequency)​
​Sensor Activates Ferromagnetic Alarm Function on Interruption of Beam​
​Gradiometers Used to Filter Out Nearby Moving Metallic Objects and Electromagnetic Signals​
​FMDS-300
Single Pillar​​Rocker Switch
​Variable Rotary Knob
​Multi-position Rotary Switch with Key, Lock​ Visual Indicators​
​Continue; Ferromagnetic ​Item Not Detected
​Stop; Ferromagnetic Item Detected
​Detection Threshold Not Exceeded
​Stop, Ferromagnetic Item Detected
(Two-tone, Nominal 2.5 kHz to 3.8 kHz Audio frequency)​
​Sensor Activates Ferromagnetic Alarm Function on Interruption of Beam​
​Gradiometers Used to Filter Out Nearby Moving Metallic Objects and Electromagnetic Signals​

 

 

 

 

Medical RF Filters http://www.ets-lindgren.com/products/shielding/medical-shielding/medical-shielding-accessories/11008/1100813Medical RF Filters
Magnetic Active Compensation System (MACS) for MRI http://www.ets-lindgren.com/products/shielding/medical-shielding/medical-shielding-accessories/11008/1100802Magnetic Active Compensation System (MACS) for MRI
SafeScan® Ferromagnetic Detection Systems http://www.ets-lindgren.com/products/shielding/medical-shielding/medical-shielding-accessories/11008/1100810SafeScan® Ferromagnetic Detection Systems
Med-Vizion™ MRI Lighting LED Sheet Lamp Recessed Troffer LFP2x2-40Khttp://www.ets-lindgren.com/products/shielding/medical-shielding/medical-shielding-accessories/11008/1100814Med-Vizion™ MRI Lighting LED Sheet Lamp Recessed Troffer LFP2x2-40K
Med-Vizion LED Down Light ZXR-3500 and ZXR-4000 http://www.ets-lindgren.com/products/shielding/medical-shielding/medical-shielding-accessories/11008/1100803Med-Vizion LED Down Light ZXR-3500 and ZXR-4000
SAFESCAN® Ferromagnetic Target Scanner™ http://www.ets-lindgren.com/products/shielding/medical-shielding/medical-shielding-accessories/11008/1100808SAFESCAN® Ferromagnetic Target Scanner™
Med-Vizion Graphic Display Panel (GDP) System http://www.ets-lindgren.com/products/shielding/medical-shielding/medical-shielding-accessories/11008/1100805Med-Vizion Graphic Display Panel (GDP) System
Med-Vizion™ MRI Lighting LED Sheet Lamp Recessed Troffer LFP2x4-40K http://www.ets-lindgren.com/products/shielding/medical-shielding/medical-shielding-accessories/11008/1100815Med-Vizion™ MRI Lighting LED Sheet Lamp Recessed Troffer LFP2x4-40K
OMS™ Sample Draw Oxygen Monitoring System http://www.ets-lindgren.com/products/shielding/medical-shielding/medical-shielding-accessories/11008/1100806OMS™ Sample Draw Oxygen Monitoring System
Automatic Opener/Closer For use with Auto-Seal II Doorhttp://www.ets-lindgren.com/products/shielding/medical-shielding/medical-shielding-accessories/11008/1100801Automatic Opener/Closer For use with Auto-Seal II Door
Safe IV Port for Medical Applications http://www.ets-lindgren.com/products/shielding/medical-shielding/medical-shielding-accessories/11008/1100809Safe IV Port for Medical Applications
CCTV Intercom System http://www.ets-lindgren.com/products/shielding/medical-shielding/medical-shielding-accessories/11008/1100804CCTV Intercom System
EMI/RFI Shielded Waveguide Air Vents http://www.ets-lindgren.com/products/shielding/medical-shielding/medical-shielding-accessories/11008/1100811EMI/RFI Shielded Waveguide Air Vents

Key Features


  • Extremely Sensitive Ferromagnetic Detection Circuitry Reduces False Alarms
  • Sensor Activates Ferromagnetic Alarm Function on Interruption of Beam
  • Patented Gradiometers Further Reduce “Nuisance” Alarms
  • Distracting Flashing Lights and Audio Alerts are Reduced
  • Adjustable Sensitivity Controls are Lockable with a Key Choice of Pass-through and Pass-by Models
  • Provide Flexible Placement Options
  • No Special Electrical Preparation is Required; Plugs into Existing Outlets