Key Product Information


​​Materials

A heavier 55.88 cm x 55.88 cm x .038 cm (22 in x 22 in x .015 in) copper wire mesh is offered for applications which require the advantages of screen, with the best possible high frequency microwave and improved low frequency magnetic attenuation characteristics.

Doors

The DEI door employs a number of unique proprietary and patented features which contribute to its superior performance characteristics and durability. All hardware and door seals are designed to maintain electrical isolation between the inner and outer shields. Doors are side hinged and supported by three heavy duty hinges to provide sag-free mounting and have been cycle tested up to 25,000 operations.
A three-point roller bearing latching system applies uniform pressure to two sets of spring temper phosphor bronze contact fingers to provide leak-proof seals for both the inner and outer shields.

The three-point clamping system draws the door into a closed position when the 71.12 cm (28 in) panic type handle is pulled up with a force of less than 30 pounds. A positive opening pressure is applied to the door when the handle is pushed down to open. The handle and lever arms, which apply clamping pressure, are adjustable as are the contact fingers. Single, double and vestibule door systems are available in most sizes and with a variety of options, including color-coordinated or wood-grained veneer finishes, view windows, access openings, ramps, locks, alarms, interlocks and microwave absorber seals. Flush floor systems are also optional. Optional auto latch door available.

Standard Construction

The basis of ETS-Lindgren's DEI construction is its unique patented design, which permits double shield enclosures to be assembled from individual panels. Panels are designed to accommodate a variety of shielding materials which are attached to a strong, non-conductive wood frame. When the shielding is overlapped and the panels bolted together, a resilient, as opposed to rigid, clamping pressure is applied, making it easier to achieve and maintain an RF tight seal. This design requires 45.72 cm (18 in) of space around the perimeter for assembly.
On midwall and ceiling panels, an angle bar clamping system is used that also provides additional structural support. Individual panels can be easily modified to accommodate accessories and special enclosure size requirements.

Inside Bolting Construction

This optional construction style enables the enclosure to be completely assembled from the inside, to accommodate areas with tight restrictions. This design employs separate clamping strips to interconnect panels. In other aspects, it is similar to standard construction and maintains the DEI principle.

Floor

Special care is taken to protect the inside floor shield by covering it with a layer of .953 cm (.375 in) plywood. A separate walking surface consists of.317 cm (.125 in) vinyl tile on 1.9 cm (.75 in) A-C plywood panels, which are interconnected with .317 cm (.125 in) aluminum strips, to ensure a flush, durable floor capable of supporting 453.59 kg (1,000 lb) per square foot. Floors can be strengthened to accommodate heavier loads when required.

Specifications Select a tab below for more information



Exterior Shield: Copper Screen
Interior Shield: Copper Screen
Magnetic (14 kHz): 68 dB
Electric (14kHz): 120 dB
Planewave 450 MHz: 110 to 120 dB
Planewave 1 GHz: 90 to 110 dB
Microwave 10 GHz: 50 to 80 dB
​Standard Enclosures Sizes (Outside Dimensions)
Model
​Height
​Length
​Width
​8
​​2.48 m (8.14 ft)​
​2.34 m (7.68 ft)​
​​1.13 m (3.71 ft)
​12
​2.48 m (8.14 ft)
​2.15 m (7.05 ft)
​2.15 m (7.05 ft)
​14
​2.48 m (8.14 ft)
​3.16 m (10.37 ft)
2.15 m (7.05 ft)​
​18
​2.48 m (8.14 ft)
​3.16 m (10.37 ft)
​​3.16 m (10.37 ft)
​22
​2.48 m (8.14 ft)
​3.16 m (10.37 ft)
​4.19 m (13.75 ft)
​26
​2.48 m (8.14 ft)
​3.16 m (10.37 ft)
​​5.21 m (17.09 ft)
​30
​2.48 m (8.14 ft)
​3.16 m (10.37 ft)
​6.22 m (20.41 ft
​34
​2.48 m (8.14 ft)
​3.16 m (10.37 ft)
​7.75 m (25.43 ft)
​38
​2.48 m (8.14 ft)
​3.16 m (10.37 ft)
​8.26 m (27.10 ft)​
​42
​​2.48 m (8.14 ft)​
​3.16 m (10.37 ft)
​9.28 m (30.45 ft)

​ 
Large Panel Enclosures Sizes (Outside Dimensions)
Model
​Height
​Length
​Width
​8W
​​2.48 m (8.14 ft)​
​2.55 m (8.37 ft)​
​​1.33 m (4.36 ft)
​12W
​2.48 m (8.14 ft)
2.55 m (8.37 ft)
2.55 m (8.37 ft)
​14W
​2.48 m (8.14 ft)
​3.77 m (12.37 ft)
2.55 m (8.37 ft)
​18W
​2.48 m (8.14 ft)
​​3.77 m (12.37 ft)
​​3.77 m (12.37 ft)
​22W
​2.48 m (8.14 ft)
​3.77 m (12.37 ft)
​4.99 m (16.37 ft)
​26W
​2.48 m (8.14 ft)
​3.77 m (12.37 ft)
​​6.22 m (20.41 ft
​30W
​2.48 m (8.14 ft)
​​3.77 m (12.37 ft)
​7.44 m (24.41 ft
​34W
​2.48 m (8.14 ft)
2.51 m (8.23 ft)
​8.66 m (28.41 ft)
​38W
​2.48 m (8.14 ft)
​​3.77 m (12.37 ft)
​9.88 m (32.41 ft)​
​42W
​​2.48 m (8.14 ft)​
​3.77 m (12.37 ft)
11.10 m (36.42 ft)

  • Non-standard Sizes on Request, up to 3.0 m x 3.0 m (9.84 ft x 9.84 ft) with Special Constructions
  • Pneumatic Operation Systems PNL-1 and PNL-3 
  • Locking Systems: Code Lock, Card Lock, etc. (Requires PNL-3 Operation System)
  • Microswitch Indicating the RF-tight Open/Closed Status of the Door
  • Slope Ramp in Front


 

 

5240 Tabletop Test Enclosure for Industrial Config ​ETS-Lindgren's Series 5240 RF-Shielded Tabletop Test Enclosures for industrial are high performance, portable shielded enclosures designed for fast, convenient EMI/RFI testing and verification.​​
DEI Enclosures ETS-Lindgren's standard modular or custom DEI screen industrial shielding enclosures provide the highest shielding performance available in a "hear-through, see-through" structure. 
EMP Mitigation-Red Edge Pulse Protection<p>​​Red Edge™ products stand alone by offering the highest protection level possible for your data systems and business equipment, which was previously only available to government and military facilities.</p>
Series 101 Shielded Rooms ETS-Lindgren's Series 101 RF Shielded Construction System meets and substantially exceeds all RF shielding requirements. The system consists of modular, hot galvanized rigid steel structural panels.
Series 71 Shielded Rooms ​​The Series 71 Copper Screen Room is designed to provide a radio-silent environment to perform electronic product trouble-shooting as well as conducted emissions and radiated emissions EMC testing.
Series 81 RF Shielded Enclosures<p>ETS-Lindgren's Series 81 RF Shielded Enclosure uses a time-proven design for superior Radio Frequency Shielding and EMI Shielding applications.</p>
Series 83 Shielded Rooms ​​​ETS-Lindgren's Series 83 RF Shielded Enclosures are a fully-custom shielding option for specialized applications such as electron microscopes and physiological studies.
Welded Fabrication Enclosures <p>ETS-Lindgren's Welded Fabrication Enclosures combine the welded fabrication concept with full-service capabilities ranging from initial consultation, design, engineering, and fabrication to final testing certification to provide maximum shielding effectiveness over many years of service.</p>

Key Features


  • Patented Double Electrically Isolated (DEI) Modular Enclosures 
  • Double Electrically Isolated (DEI) Enclosures for Maximum Effectiveness 
  • Durable, Expandable, Easy to Assemble, Easy to Move
  • Resilient Clamping System 
  • DEI Concept Provides a Hear-through See-through Working Environment

Literature and Videos


 

 

http://www.ets-lindgren.com/products/shielding/industrial-shielding/rf-shielded-enclosures/11003/1100301<a href="/sites/etsauthor/ProductBrochures/General%20Brochures/Test_and_Measurement_Full_Line.pdf"><img alt="" src="/_layouts/15/IMAGES/icpdf.png" />Test_and_Measurement_Full_Line.pdf</a>

 

 

http://www.ets-lindgren.com/products/shielding/industrial-shielding/rf-shielded-enclosures/11003/1100301

L o a d i n g

 Catalog-Item Reuse