Key Product Information


​​Safety

For safety and security, the ASDS comes with the industry standard key and thumb latch door hardware. The door can be installed as an in-swing or out-swing door.

Another option is the 0.6 m x 0.6 m (2 ft x 2 ft) RF view window that can be placed within the door. The RF view window uses safety glass and double layer screen mesh to achieve RF performance.

Applications

Available in various sizes and configurations, the ASDS can fulfill many needs. While typically sold in a 1.2 m x 2.13 m (4 ft x 7 ft) size, it is also available in 0.9 m x 2.13 m (3 ft x 7 ft) , 1.06 m x 2.13 m (3.5 ft x 7 ft), and 1.52 m x 2.13 m (5 ft x 7 ft) as a stocked item. Other widths and heights are available but may require some additional design and manufacturing time.
Typically, a shielded office or conference room environment utilizes a single door for entry, however the ASDS is also available as a double door if additional space is needed. Again, a variety of door sizes and combinations are available:

  • Dual 1.2 m (4 ft) Door Leafs
  • 1.2 m and 0.9 m (4 ft and 3 ft) Leafs
  • 1.2 m and 0.6 m (4 ft and 2 ft) Leafs

If your size differs from above, please contact your ETS-Lindgren representative to discuss your custom door requirements. The ASDS door is suitable for shielded office or conference room environments.
The door easily and simply ties into existing RF shields with a typical installation time of a single day, two if the RF shield is not an ETS-Lindgren shield. 

Performance

The ASDS door RF attenuation is 60dB @ 1GHz when tested in accordance with MIL-STD-285/IEEE-299. If you have questions, or are unsure about your requirements, please contact an ETS-Lindgren representative for the appropriate RF door.

​System Installation

With a new RF shield, installation of the ASDS door requires a single day. It easily and simply ties into existing RF shields. To modify an existing RF shield, the installation typically requires a single day for an ETS-Lindgren shield and can increase to two or more days for non-ETS-Lindgren shields. Installations are site specific and vary.

Key Features


  • Attenuation of 60 dB at 1 GHz, when Tested in Accordance with MIL-STD-285/IEEE-299
  • Lightweight Door with a Low-profile Door Threshold
  • Key and Thumb Latch Door Hardware for Safety and Security
  • Optional STC 32 and 37 Acoustic Versions are Available
  • Available in a Variety of Sizes and in a Double Door Configuration

Literature and Videos


 

 

http://www.ets-lindgren.com/products/shielding/government-shielding/rf-shielded-doors-for-government/11001/1100104<a href="/sites/etsauthor/ProductBrochures/General%20Brochures/Test_and_Measurement_Full_Line.pdf"><img alt="" src="/_layouts/15/IMAGES/icpdf.png" />Test_and_Measurement_Full_Line.pdf</a>

 

 

http://www.ets-lindgren.com/products/shielding/government-shielding/rf-shielded-doors-for-government/11001/1100104

L o a d i n g