Key Product Information


​​Wide Frequency and Dynamic Ranges

EMSense is fully compatible with all ETS-Lindgren EMC E-field battery-powered probes, covering a frequency range of 10 kHz to 40 GHz and a dynamic range of 0.5 to 800 V/m.

Compact Design

Each EMSense plug-in card occupies one slot in the EMCenter platform, allowing additional slots to be occupied by modular plug-in cards for positioning controllers, multiple RF switches and more.

Specifications Select a tab below for more information



Specification
HI-6023 (Optional E-field Probe)​HI-6006
(Optional E-field Probe)

HI-6053 (Optional E-field Probe)​
​Detection
​​Isotropic (X, Y and Z Axis Readings)
​​Isotropic (X, Y and Z Axis Readings)
​​Isotropic (X, Y and Z Axis Readings)
​​Calibrated Frequency Range
​10 kHz to 1 GHz
​​100 kHz to 6 GHz 
​10 MHz to 40 GHz​
​Frequency Response (Typical)
​10 kHz to 30 kHz +0.5, - 2.5 dB 
30 kHz to 1 GHz ± 1.0 dB​



​500 kHz to 2 GHz +1.0, -2.5 dB 
2 to 5 GHz +3.5, -4.0 dB  
5 to 6 GHz +1.0, -6.0 dB ​

​10 to 100 MHz + 3.0, -4.0 dB
100 MHz to 1 GHz +3.0, -0.50 dB
1 to 18 GHz +4.0, -2.0 dB
18 to 40 GHz +3.0, -4.5 dB
​​Frequency Response with Correction
​± 0.9 dB
​± 0.9 dB
​​10 MHz to 18 GHz ±0.9 dB
18 to 40 GHz ±1.1 dB​
​Dynamic Range
​​2.0 to 800 V/m (Single Range)​
​0.5 to 800 V/m (Single Range) 
​​2.0 to 800 V/m (Single Range)
​​Resolution
​0.01 V/m​ 
​0.01 V/m​ 
​0.01 V/m​ 
​Isotropic Deviation
​±0.5 dB @ 400 MHz
​±0.5 dB @ 400 MHz
​±1.0 dB <18 GHz​
​​Linearity
​±0.5 dB @ 27 MHz​
​±0.5 dB @ 27 MHz
​±0.5 dB @ 1 GHz
​​Sample Rate ​
​60 Samples/Second Maximum​
​60 Samples/Second Maximum​
​60 Samples/Second Maximum​
​​Overload Withstand
​​>1500 V/m CW​
​​>1500 V/m CW​
​​>1500 V/m CW​

Specification
7007-001 (Plug-in Card)​ HI-6023 (Optional E-field Probe)​ HI-6006 (Optional E-field Probe)​ HI-6053 (Optional E-field Probe)
​Exterior Dimension​
​1 Slot
​​32 mm x 32 mm Housing 
(1.25 in x 1.25 in x 1.25 in)
​​32 mm x 32 mm Housing 
(1.25 in x 1.25 in x 1.25 in)
​​

76 mm x 51 mm x 51 mm

Housing (3.0 in x 2.0 in x 2.0 in)


​Sensor Protective Caps Height
​n/a
​36 mm (1.42 in)
​43 mm (1.69 in)
​348 mm x 58.4 mm (13.7 in probe length x 2.3 in width)
​Weight
​n/a
​80 g (2.82 oz) ​
​80 g (2.82 oz) ​
​360 g (12.7 oz)
​Mounting
​n/a
​​1/4” 20 - UC Internal Thread​
​​1/4” 20 - UC Internal Thread​
​​1/4” 20 - UC Internal Thread​
​Physical Interface
​n/a
​Duplex Optical Fiber
(200 Micron Multi-mode) 
FSMA Connectors
Integral 1m Optical Cable​
 

​Duplex Optical Fiber
(200 Micron Multi-mode) 
FSMA Connectors
Integral 1m Optical Cable
Duplex Optical Fiber
(200 Micron Multi-mode) 
FSMA Connectors​
​Temperature Range
​​0° C to +35° C
(32°F to +95°F)

+10º to +40° C
(+50°F to +95°F)

​+10º to +40° C
(+50°F to +95°F)

​+10º to +40° C
(+50°F to +95°F)

​Relative Humidity
​10 to 90% (Non-condensing)
​​5 to 95% (Non-condensing)​
​​5 to 95% (Non-condensing)​
​​5 to 95% (Non-condensing)​
​Battery (Field replaceable)
n/a​​Rechargeable NiMH
Rechargeable NiMHRechargeable NiMH AAA 900mA/hr
​Battery Life
n/a​8 Hours​8 Hours​30 Hours​
​Battery Charger
n/a​​100 - 240 VAC Universal Input
3-Hour Charge from Full Depletion 
​100 - 240 VAC Universal Input
3-Hour Charge from Full Depletion 
​100 - 240 VAC Universal Input
3-Hour Charge from Full Depletion 

  • EMSense EMF Probe Plug-in Card

 

 

EMCenter™ Modular RF Platform Model 7000 Series​​ETS-Lindgren's EMCenter™ is a modular RF platform consisting of an integrated micro-controller, modular chassis, and a selection of optional plug-in card modules. It can be used to perform a variety of RF measurement applications.
EMControl™ Positioner Controller Plug-in Card Model 7006-01 ​ETS-Lindgren's EMControl™ is a versatile positioner controller which enables the user to synchronize simultaneous movement of two ETS-Lindgren positioning devices (for example, towers or turntables) and On/Off operation of an additional auxiliary device (LISN, EUT, etc.).<br>
EMGen™ RF Signal Generator Model 7003-001 ​​​​​ETS-Lindgren’s EMGen™ RF Signal Generator Plug-in Card offers users a convenient and economical solution for signal generation.
EMPower™ Power Meters Model 7002-006 ETS-Lindgren has extended its range of EMPower RF power meters to comply with the measurement requirements of the ETSI 300 328 and 301 893 standards for wideband data transmission systems, including IEEE 802.11™, Bluetooth® and Zigbee™. 
EMPower™ Power Meters Model 7002-00X ​​ETS-Lindgren's EMPower™ Power Meters make fast, accurate power measurements, even at low power levels.
EMPower™ Pulse RF/Burst Power Meter Model 7002-00X ETS-Lindgren's EMPower Pulse RF/Burst Power Meter is designed to perform very fast measurements on high-frequency pulse-shaped signals (RF bursts).
EMSense™ EMF Probe Plug-in Card Model 7007-001 ​ETS-Lindgren EMSense™ EMF Probe Plug-in Card provides an interface for ETS-Lindgren’s battery-powered E-field probes to the EMCenter Modular RF Platform.
EMSense™ EMF Probe Plug-in Card Model 7007-002<p>​​ETS-Lindgren EMSense™ EMF Probe Plug-in Card provides an interface for ETS-Lindgren’s laser-powered E-field probes to the EMCenter Modular RF Platform.</p>
EMSwitch™ RF Switch Plug-in Cards 7001-00X ​​ETS-Lindgren's EMSwitch™ RF Switch Plug-in Cards are general purpose multi-channel switch matrixes, used to switch the RF path of equipment for RF measurement applications, including immunity, emissions, and wireless measurements.

Key Features


  • Provides an Interface for ETS-Lindgren Battery-Powered E-field Probes
  • Wide Frequency and Dynamic Ranges
  • Compact Design

Literature and Videos


 

 

http://www.ets-lindgren.com/products/probes-monitors/emc-probes/electric-field-probes/5010/501007<a href="/sites/etsauthor/ProductBrochures/General%20Brochures/Test_and_Measurement_Full_Line.pdf"><img alt="" src="/_layouts/15/IMAGES/icpdf.png" />Test_and_Measurement_Full_Line.pdf</a>

 

 

http://www.ets-lindgren.com/products/probes-monitors/emc-probes/electric-field-probes/5010/501007<a href="/sites/etsauthor/ProductsManuals/Probes_Monitors/fiberopticcleaning.pdf"><img alt="" src="/_layouts/15/IMAGES/icpdf.png" />Fiber Optic Cleaning</a>

L o a d i n g

 Catalog-Item Reuse