SpaceSaver™ FAR Chamber
ETS-Lindgren's SpaceSaver Far chambers are designed to perform 
IEC 61000-4-3 compliant radiated immunity measurements.

 

 


ETS-Lindgren's SpaceSaver™ FAR chambers are designed to perform IEC 61000-4-3 compliant radiated immunity measurements. Fully anechoic, these chambers can also be used for CISPR 16-1-4 pre-compliant radiated emissions measurement pre-scans, with fixed height. Frequency ranges for this chamber are 26 MHz to 40 GHz (radiated immunity) and 30 MHz to 40 GHz (radiated emission).

Key Product Information


Specifications Select a tab below for more information



Frequency Minimum: 26 MHz
Frequency Maximum: 40 GHz
Scan Height: Fixed
Overall Structure Dim (H): 3.5 m (11.48 ft)
Overall Structure Dim (L): 7.8 m (25.59 ft)
Overall Structure Dim (W): 3.8 m (12.47 ft)
Internal Working Area (L): 7.6 m (24.93 ft)
Internal Working Area (W): 3.7 m (12.14 ft)
Internal Working Area (H): 3.4 m (11.15 ft)
Quiet Zone for Emission Testing (Diameter x H): 1.0 m x 0.5 m
(3.3 ft x 1.6 ft)
Field Uniformity: 0 to 6 dB; 1.5 m x 1.5 m (4.92 ft to 4.92 ft)
  • Two Connector Panels, 15 cm x 61 cm (6 in x 24 in) Clear Opening
  • Four Corner-mounted Light Fixtures with Floodlights (Electrical Distribution not Included)
  • 4 x 2 x 30 Amp, Power-Line Filters For Lights And EUT (Wiring Not Included)
  • One Single-leaf, Series 201, Recessed Contact Mechanism (RCM), Manually Operated, RF-shielded Door, 0.91 m x 2.13 m (3 ft x 7 ft) Clear Opening
  • Two Waveguide Vents, 30.48 cm x 30.48 cm (12 ft x 12 ft) in the Ceiling
  • 7-TR Tripod
  • Shield Test Per IEEE-299/MIL-STD 285
  • One 3.81 cm (1.5 in) Pipe Penetration with Flange Nuts and Cap
  • Two "N" Type Connectors
  • Sliding Doors for Flush-threshold Opening
  • Fire Detection and Suppression Systems
  • Immunity Interlock Switch
  • Chamber Testing (See Performance Tables)
  • Heating, Ventilation, & Air Conditioning (HVAC) Systems
  • Electrical Distribution
  • CCTV Monitoring System
  • Raised Reflective Ground Plane Floor System
  • Various Sizes of Series 201 RF Shielded Swing Doors
  • Intercom System
  • Structural Design Calculations and Certification
  • Additional Filtering
  • Polystyrene Wall Covering Over Ferrite
  • Antennas
    • Immunity Only
      • 3109 Biconical 
      • 3148B Log Periodic 
    • Emissions Only 
      • 3110C Biconical 
      • 3148B Log Periodic 
    • Immunity and Emissions 
      • 3104C Biconical (50 w max.) 
      • 3148B Log Periodic 
      • 3142D Log Periodic
  • Towers and Tripods 
    • Immunity Only 
      • 4-TR Tripod 
  • Positioners 
    • Low Reflective Table 
    • 2165-1.21, LoPro 1.2 m Diameter 
    • 2188-1.23, 1.2 m Diameter; Requires 160 mm (6 in) Raised Floor 
    • 2188-1.53, 1.5 m Diameter; Requires 160 mm (6 in) Raised Floor
  • Probes 
    • HI-6005 
    • HI-6105

 

 

SpaceSaver™ 26H Chamber http://www.ets-lindgren.com/products/chambers/emc-chambers/spacesaver™-chambers/5005/500501SpaceSaver™ 26H Chamber
SpaceSaver™ PC Chamber http://www.ets-lindgren.com/products/chambers/emc-chambers/spacesaver™-chambers/5005/500503SpaceSaver™ PC Chamber
SpaceSaver™ FAR Chamber http://www.ets-lindgren.com/products/chambers/emc-chambers/spacesaver™-chambers/5005/500502SpaceSaver™ FAR Chamber

Key Features


  • Ultra Broadband Frequency Range: 26 MHz to 40 GHz Radiated Immunity Compliance:
    • IEC 61000-4-3
  • Radiated Emissions Pre-Compliance:
    • Semi Anechoic (Pre-Scan)
    • ANSI C63.4/CISPR 16-1-4
    • Fully Anechoic
    • CISPR 16-1-4 (Fixed Height) 
  • Turnkey Chamber Solutions

Literature and Videos


 

 

http://www.ets-lindgren.com/products/chambers/emc-chambers/spacesaver™-chambers/5005/500502<a href="/sites/etsauthor/ProductBrochures/General%20Brochures/Test_and_Measurement_Full_Line.pdf"><img alt="" src="/_layouts/15/IMAGES/icpdf.png" />Test_and_Measurement_Full_Line.pdf</a>

 

 

http://www.ets-lindgren.com/products/chambers/emc-chambers/spacesaver™-chambers/5005/500502

L o a d i n g

 Catalog-Item Reuse