FACT™ 10 Chambers
​​ETS-Lindgren FACT™ 10 Chambers offer semi-anechoic radiated emissions (RE) and fully anechoic radiated immunity (RI) compliance test capability for most international EMC compliance regulations.

 

 


​​​ETS-Lindgren FACT 10 Chambers offer semi-anechoic radiated emissions (RE) and fully anechoic radiated immunity (RI) compliance test capability for most international EMC compliance regulations. The chamber's small overall size results from the use of ETS-Lindgren hybrid absorber ferrite tiles, which require less volumetric space than traditional absorbers. FACT 10 chambers are large enough to perform 6 meter antenna scans above the ground plane. These chambers can also accommodate large diameter turntables for testing substantial EUTs.

FACT 10 chambers achieve their broadband performance using a unique arrangement of hybrid and ferrite tile absorber. The design was modeled using the proprietary numerical electromagnetic software responsible for creating chambers that set new standards for anechoic performance.

At 10 meter range lengths, ETS-Lindgren guarantees a Normalized Site Attenuation (NSA) better than ± 3.0 dB deviation from theoretical NSA within a cylindrical quiet zone of 3 m in diameter over the frequency range of 30 MHz to 1 GHz. The quiet zone at 3 and 5 meter test distances is cylinder up to 2.0 meter in diameter, following the volumetric test procedure of ANSI C63.4-2000.

Anticipating tomorrow's requirements, the FerroSorb™ hybrid and FT series ferrite tile absorbers used in this chamber to also guarantee NSA performance of better than ± 4 dB deviation from theoretical NSA using the test method defined in ANSI C63.4-2000 at the extended frequency range of 1 to 40 GHz.

Key Product Information


Specifications Select a tab below for more information



Frequency Minimum: 26 MHz
Frequency Maximum: 18 GHz
Absorber Type: EHP-18CL Absorber; FS-1500; FT-100; FT-100c; FT-2000
IEC 1000-4-3 Field Uniformity: 0+6 dB; 1.5 m x 1.5 m (3.92 ft x 3.92 ft); 26 MHz to 18 GHz; 75% 16 Points
  • 3 m Quiet Zone
    • Design and fabricate RF-shielded enclosure, interior nominal shield-to-shield dimensions of 18.78 m L x 11.56 m W x 8.93 m H (61.6 ft x 37.8 ft x 29.3 ft) includes 45.72 cm (18 in) raised floor.
  • 4 m Quiet Zone:
    • Design and fabricate RF-shielded enclosure, interior nominal shield-to-shield dimensions of 19.42 m L x 12.17 m W x 8.93 m H (63.6 ft x 39.8 ft x 27.8 ft) includes 45.72 cm (18 in) raised floor.
  • 6 m Quiet Zone: 
    • Design and fabricate RF-shielded enclosure, interior nominal shield-to-shield dimensions of 21.82 m L x 13.28 m W x 9.10 m H (71.5 ft x 43.5 ft x 29.8 ft) includes 60.96 (24 in) raised floor.
  • Two Access Hatches in Raised Floor
  • Dielectric Vapor Barrier and Masonite Underlayment
  • Model 2175 MiniMast™ Electrically Powered Air Polarization Boom Tower with 20 m Cable and Fiber Optic Feed-through
  • One RF-shielded Penetration for Airline to MiniMast (Compressed Air is Responsibility of Customer)
  • Two Door Maintenance Kits
  • One Threaded Brass Ground Stud 1.27 cm (0.5 in) Diameter x 12.7 cm (5 in) Long
  • One Single-leaf, Series 201, Recessed Contact Mechanism (RCM), Manually Operated, RF-Shielded Personnel Door, .91 m x 2.13 m (3 ft x 7 ft) Clear Opening
  • FT-1500 on the Doors
  • Raised, Reflective Ground Plane, 45.72 cm (18 in)
  • Model 2090 Dual Device Controller
  • Four "N" Type Connectors
  • Design and Fabricate RF-shielded Enclosure, Interior Nominal Shield-to-shield Dimensions of 18.81 m L x 11.56 m W x 6.97 m H, (61.71 ft x 37.93 ft x 22.87 ft) includes 45.72 cm (18 in) Raised Floor
  • Four Single Line, 100 Amp, 60 Hz, Power-line Filters (Wiring not included)
  • Two 2 x 30 Amp, 60 Hz Power-line Filters for Turntable (Wiring not included)
  • FS-1500 Hybrid Absorber for all Four Walls up to the 9th Row
  • Light Reflective Covers for the FS-1500, Hybrid Absorber on the Chamber Walls
  • Sixteen Pieces of EHP-18PCL Pyramidal Absorber on an Area of the Floor for Radiated Immunity Testing from 1 GHz up to 40 GHz
  • FT-100 from the 9th Row to Ceiling for all Four Walls
  • Installation of the Enclosure and Absorber
  • One RFSD-F-100 Automatic, Sliding RF-shielded Equipment Door
  • 3.18 mm (.125 in) Vinyl Floor Tile
  • Four Waveguide Vents, 60.96 cm x 30.48 cm (24 in x 12 in)
  • Field Uniformity Calibration per IEC 61000-4-3 from 26 MHz to 1 GHz (Optional Test from 1 GHz to 18 GHz)
  • Seismic Structural Design Calculations and Certification
  • One Connector Panel, 30.48 cm x 60.96 cm (12 in x 24 in)
  • One Fiber Optic Penetration Kit
  • One Design Review at Customer's Location
  • 2081-3.03 Electrically Powered, 3 m Turntable with Cable and Fiber Optic Feed-through
  • Normalized Site Attenuation Test per ANSI C63.4-2000 from 30 MHz to 1 GHz (Optional Test from 1 GHz to 18 GHz)
  • One 3.81 cm (1.5 in) Pipe Penetration with Flange Nuts and Cap
  • Shield Test per MIL-STD-285, One Frequency Test at 1 GHz
  • Twelve High-hat Light Fixtures with Integral Waveguide Air Vents (Electrical Distribution not included)
  • Guaranteed Performance and a Five-year Limited Warranty; One-year Warranty on Doors, Filters and Moving Parts; Two-year Warranty on Optional ETS-Lindgren Equipment
  • ETS-Lindgren 3126 Dipole Antenna Sets for Use in Chamber Calibration
  • Shielded Control Room
  • Structural Design Calculations and Certification Sealed by a Registered Professional Engineer

 

 

FACT™ 3 with 2 M QZ Chambers http://www.ets-lindgren.com/products/chambers/emc-chambers/fact™-chambers/5004/500401FACT™ 3 with 2 M QZ Chambers
FACT™ 5 Chambers http://www.ets-lindgren.com/products/chambers/emc-chambers/fact™-chambers/5004/500404FACT™ 5 Chambers
FACT™ 10 Chambers http://www.ets-lindgren.com/products/chambers/emc-chambers/fact™-chambers/5004/500402FACT™ 10 Chambers
FACT™ 25 CISPR Chambers http://www.ets-lindgren.com/products/chambers/emc-chambers/fact™-chambers/5004/500403FACT™ 25 CISPR Chambers

Key Features


  • 26 MHz to 18 GHz Performance Range 
  • Full Compliance Testing for Radiated Emissions:
    • ANSI C63.4 (2000) Part 15 & 18
    • CISPR 11/EN55011, CISPR16/EN55016
    • CISPR 22/EN55022, EN50147- 2
  • MIL-STD 461E, Belcore GR - 1089, SAE J551 
  • Available as a Turnkey Package:
  • Full Compliance Testing for Radiated Immunity:
    • IEC 61000-4-3/EN61000-4-3
    • SAE J551
    • SAE J-1113 
  • Eligible for FCC 3 Meter Class A & B (3 & 10 m Test Methods) Facility Filing