Key Product Information


Specifications Select a tab below for more information



Frequency Range: 10 kHz to 400 MHz
Nominal Output Power: 260W
Gain Variation±3 dB
Harmonics-20 dBc Maximum
Output Impedance50 Ω
Input VSWR2:1 Maximum
AC Supply100 to 250 VAC, Single Phase
Supply Frequency Range50/60 Hz
Line Power<2 kVA
Dimensions19 in, 6U Case, 440 mm (17.3 in) Deep
Weight30.0 kg (66.1 lb)
Case Style (Standard)Rack Mount with Rear Panel Connectors 
Case Style (Optional)Bench Mount, Front Panel Connectors


Key Features


  • ISO 11452-4, 300 mA
  • Ideal for BCI Testing
  • Mismatch Tolerant and Unconditionally Stable
  • Rugged Design for EMC Testing 

Literature and Videos


 

 

http://www.ets-lindgren.com/products/amplifiers/9-khz-to-400-mhz/3002/300230<a href="/sites/etsauthor/ProductBrochures/General%20Brochures/Test_and_Measurement_Full_Line.pdf"><img alt="" src="/_layouts/15/IMAGES/icpdf.png" />Test_and_Measurement_Full_Line.pdf</a>

 

 

http://www.ets-lindgren.com/products/amplifiers/9-khz-to-400-mhz/3002/300230<a href="/sites/etsauthor/ProductsManuals/Amplifiers/Remote%20Control%20Interface%20399639.pdf"><img alt="" src="/_layouts/15/IMAGES/icpdf.png" />Remote Control Interface Manual</a>