AMS-8050 Antenna Measurement System

Model AMS-8050 The ETS-Lindgren Model AMS-8050 Antenna Measurement System is compact, fully anechoic RF enclosure for antenna pattern measurements.


Request for Quote Request for Quote

    Print Version - all info Print Version - all info
Request for Quote Ask a Question

AMS-8050 Datasheet AMS-8050 Antenna Measurement System Datasheet

Key Features

  • Compact, anechoic absorber-lined RF enclosure
  • Efficient Over-the-Air Antenna Pattern Measurement
  • EMQuest™ Data Acquisition and Analysis Software
  • Ideal as a shared resource for Pre-Compliance testing
  • No special installation of construction required
  • Self-contained, built on a moveable cart system
  • Test Measures: - Active and Passive Antennas
    - 2-D/3-D Antenna Patterns
    - Antenna Pattern Measurement
    Vector and Scalar Quantities
    - TRP,EIRP
    - TIS,EIS
    - NHPRP,NHPIS

Description

The AMS-8050 Antenna Measurement System is freestanding and built on a moveable cart configuration; it fits into parent buildings without special installation or construction. This over-the-air test system for wireless device measurement may be used for:

* Rapid prototyping of wireless devices
* Design validation
* Pre-certification testing
* Performance measurement
* Production sampling

The AMS-8050 Antenna Measurement System is an ideal solution when space is a limitation as it is a self-contained, test lab for making fast, over-the- air performance measurements of small wireless devices and mobile handsets, as well as short range APM. Integrated drawers allow components required for testing to remain with the system. It is incorporated into a movable chassis so the entire system may be transported between different test stations. The ability to transport the system and store all components within the cart makes it an ideal solution for multiple research and development groups.

Small in size but big on operational throughput, the AMS 8050 Antenna Measurement System lets you make fully automated 2-D (polar) and 3-D (spherical) antenna pattern measurements. You can measure quantities such as : total radiated power (TRP), effective isotropic radiated power (EIRP), total isotropic sensitivity (TIS), effective isotropic sensitivity (EIS), near-horizon partial radiated power (NHPRP), and near-horizon partial isotropic sensitivity (NHPIS). If you're using an external test house for certification testing, our system can help you go fully prepared. Over-the-air measurements made in the AMS 8050 have shown good correlation to measurements made in larger, fully compliant chambers. Use the AMS-8050 Antenna Measurement System to make tests during product development, and you'll shorten the time to certification.

ams8050 systems diagram

System diagram. Top cut view of the AMS-8050 anechoic chamber and test instrumentation (Shown with customer-supplied computer, wireless communications tester, spectrum analyzer, vector network analyzer and cables. Model 2090 Controller–OPT1 and cables shown in black are included with the system.

2

Data Acquisition and Analysis Software

The AMS 8050 System includes our versatile EMQ 100 Antenna Pattern Measurement Software. The software makes fully automated (pattern and frequency response) measurements for both active and passive antennas, including their vector and scalar qualities, in either transmit or receive mode.

Post-processing capabilities include calculations for directivity, gain, radiation efficiency, total radiated power and total isotropic sensitivity. EMQ 100 also calculates industry specific quantities such as Near-Horizon Partial Radiated Power and Near- Horizon Partial Isotropic Sensitivity required by the CTIA Over-The-Air Performance Test Plan.

Advanced graphic capabilities allow data to be shown in a variety of 2-D and 3-D formats, exported to Microsoft Excel™, PDF files or saved in Microsoft RTF format.

1

Measurement Capability

Scalar Pattern Measurements

• Single-Axis Single-Polarization Pattern Measurement
• Single-Axis Dual-Polarization Pattern Measurement
• Two-Axis Single-Polarization Pattern Measurement
• Two-Axis Dual-Polarization Pattern Measurement

Vector Pattern Measurements

• Vector Single-Axis Single-Polarization Pattern Measurement
• Vector Single-Axis Dual-Polarization Pattern Measurement
• Vector Two-Axis Single-Polarization Pattern Measurement
• Vector Two-Axis Dual-Polarization Pattern Measurement

Sensitivity Pattern Measurements

• Single-Axis Single-Polarization Sensitivity Pattern Measurement
• Single-Axis Dual-Polarization Sensitivity Pattern Measurement
• Two-Axis Single-Polarization Sensitivity Pattern Measurement
• Two-Axis Dual-Polarization Sensitivity Pattern Measurement

Response Measurements

• Response Measurements
• Vector Response Measurements
• Full S-Parameter Measurement
• Communication Tester Frequency Response Measurement

AMS-8050 Diagram

Special Note: The dimensions illustrated are the minimum clearances required, with a small allowance on each side to pass the system through doorways and corridors. If these dimensions are not met, the AMS-8050 may be split into two sections (System Cart, Drive Cart). Contact ETS-Lindgren Sales at the time of order if you determine there is a need to split the system.


CAUTION: If using an elevator to locate the system, verify the elevator will accommodate the size and weight ( 816.5 kg/1800 lb) of the system and accompanying personnel before attempting the movement.