Product Image

Key Features

  • For 2 to 12 Line LTC Filters
  • Signal, Sensor & Voice Communication
  • Control Line
  • Download PDF Datasheet
  • ETS-Lindgren's LTC Series are ideal for applications including EMC testing, communication lines entering or leaving shielded rooms, computer rooms, communication terminal rooms, and Sensitive Compartmental Information Facilities (SCIF). The LTC-X640 series filters have multiple circuits to handle 2, 4, 6, 8, 10 or 12 wires, and are designed for stand-alone, individual mounting. The LTC-X640 series filters may be supplied with an optional threaded conduit pipe for penetration of a shielded enclosure.

    Specifications
    View the Signal and Sensor Lines Filters technical specifications below

    Physical Specifications

    Model
    Number of Lines
    Width
    LTC-2640-100Z
    2
    7.62 cm (3.0 in)
    LTC-4640-100Z
    4
    15.24 cm (6.0 in)
    LTC-6640-100Z
    6
    30.48 cm (12 in)
    LTC-8640-100Z
    8
    30.48 cm (12 in)
    LTC-10640-100Z
    10
    45.72 cm (18 in)
    LTC-12640-100Z
    1245.72 cm (18 in)
    LTC-2640-200Z
    2
    7.62 cm (3.0 in)
    LTC-4640-200Z
    4
    5.24 cm (6.0 in)
    LTC-6640-200Z
    6
    30.48 cm (12 in)
    LTC-8640-200Z
    8
    30.48 cm (12 in)
    LTC-10640-200Z
    10
    45.72 cm (18 in)
    LTC-12640-200Z
    12
    45.72 cm (18 in)
    LTC-2640-300Z
    2
    7.62 cm (3.0 in)
    LTC-4640-300Z
    4
    5.24 cm (6.0 in)
    LTC-6640-300Z
    6
    30.48 cm (12 in)
    LTC-8640-300Z
    8
    30.48 cm (12 in)
    LTC-10640-300Z
    10
    45.72 cm (18 in)
    LTC-12640-300Z
    12
    45.72 cm (18 in)

    NOTE: For Installation on shield, filters can be ordered with penetration kit. Add "/PEN" to model numbers

    Electrical Specifications


    Model

    Passband

    Impedance

          Passband

        Loss

         Stopband

              Insertion Loss    

    Max

    Current

    Max

          Voltage

    LTC-X640-100Z     

    20(L-L)
    10(L-G)

    1.0 dB

    Maximum
    0 to 4 kHz

         100 dB Minimum @

          14 kHz to 18 GHz

    0.5

    125 VAC

    LTC-X640-200Z     

    200(L-L)
    100(L-G)

    1.0 dB

    Maximum
    0 to 4 kHz

          100 dB Minimum @

           14 kHz to 18 GHz

    0.8

    125

    LTC-X640-300Z     

    300(L-L)
    150(L-G)

    1.0 dB

    Maximum
    0 to 4 kHz

          100 dB Minimum @

           14 kHz to 18 GHz

    0.8

    125


    Charts
    View the Signal and Sensor Lines Filters charts below