EMP Commercial and Defense Non-Tempest Powerline Filters - ETS-Lindgren
EMP Commercial and Defense Non-Tempest Powerline Filters
Product Image
Key Features
  • Protects Against Damage from EMP:
    • HEMP
    • IEMI
  • Wide Selection of Current Ratings: 10 Amps to 1200 Amps
  • Meets or Exceeds MIL-STD-188-125, Hardness Critical Item (HCI), 1 & 2 Point-of-Entry Requirements
  • Acceptance Tested at Little Mountain Test Facility, Hill AFB, Ogden, UT
  • Superior Red Edge Performance Features
  • For Defense (non-TEMPEST) and Commercial Applications

ETS-Lindgren's Pulse Protected Powerline Filters with Red Edge Technology protects against damage to electronic equipment and loss of data caused by a sudden and intense electromagnetic pulse (EMP) and Intentional Electromagnetic Interference (IEMI). These filters provide excellent multi-stage, over-voltage, and EMI/ RFI protection. ETS-Lindgren is the only manufacturer to have their filters acceptance tested to the requirements of MIL-STD-188-125 by Little Mountain Test Facility operated by Boeing at Hill Air Force Base, in Ogden, Utah (test report available on request).

Product Features

Red Edge Pulse Protection

Our Red Edge advantage includes the knowledge and expertise gained from almost 90 years of designing and building RF shield and filter solutions for demanding defense and commercial applications.​ 


EMP Pulse Protection

The filter unit is fitted with inductive input circuit and ESA, resulting in very low residual currents during an EMP pulse, protecting connected equipment.​  

 

Insertion Loss Performance as Required by MIL-STD-188-125 1 & 2

Our filters provide 80 dB of insertion loss across a frequency range of 10 MHz to 1 GHz and 100 dB from 1 GHz to 20 GHz in symmetric and asymmetric mode per MIL-STD-220.​ 

 

High Frequency Response Design

Better frequency response is achieved with the use of a high frequency feed-through capacitor design.​ Extended filter life oversized inductors are used for low loss and low temperature rise which extends filter life. Filter life is further extended with the use of self-healing capacitors.​​​

 

Meets or Exceeds These Standards

MIL-STD-188-125 1 & 2 

Defense Standard 59-188 1 & 2 

MIL-STD-F15733

Specifications
Physical Specifications


Model
Wires
Wall Mount Cabinet
Floor Mount
Nominal Dimensions 
HEMP-2010
2YesNo43 cm x 10 cm x 8 cm (17 in x 4 in x 3 in)
HEMP-2030
2YesNo51 cm x 13 cm x 9 cm (21 in x 5 in x 3.5 in)
HEMP-3030
3Yes
No53 cm x 25 cm x 9 cm (21 in x 10 in x 3.5 in)
HEMP-4030
4Yes
No
53 cm x 25 cm x 9 cm (21 in x 10 in x 3.5 in)
HEMP-2060
2
Yes
No
107 cm x 25 cm x 25 cm  (2 in x 10 in x 10 in)
HEMP-3060
3Yes
No
107 cm x 51 cm x 25 cm (42 in x 20 in x 10 in)
HEMP-4060
4Yes
No
107 cm x 51 cm x 25 cm (42 in x 20 in x 10 in)
HEMP-2100
2Yes
No
107 cm x 25 cm x 25 cm (42 in x 10 in x 10 in)
HEMP-3100
3Yes
No
107 cm x 51 cm x 25 cm (42 in x 20 in x 10 in)
HEMP-4100
4Yes
No
107 cm x 51 cm x 25 cm (42 in x 20 in x 10 in)
HEMP-3250
3Yes
No
152 cm x 61 cm x 25 cm (60 in x 24 in x 10 in)
HEMP-4250
4Yes
No
152 cm x 61 cm x 25 cm (60 in x 24 in x 10 in)
HEMP-3X400
3Yes
Yes173 cm x 86 cm x 30 cm (68 in x 34 in x 12 in)
HEMP-4X400
4Yes
Yes
173 cm x 86 cm x 30 cm (68 in x 34 in x 12 in)
HEMP-3X600
3Yes
Yes
224 cm x 114 cm x 46 cm (88 in x 45 in x 18 in)
HEMP-4X600
4Yes
Yes
224 cm x 114 cm x 46 cm (88 in x 45 in x 18 in)
HEMP-3X800
3Yes
Yes
224 cm x 114 cm x 46 cm (88 in x 45 in x 18 in)
HEMP-4X800
4Yes
Yes
224 cm x 114 cm x 46 cm (88 in x 45 in x 18 in)
HEMP-3X1200
3Yes
Yes
257 cm x 135 cm x 61 cm (101 in x 53 in x 24 in)
HEMP-4X1200
4Yes
Yes
257 cm x 135 cm x 61 cm (101 in x 53 in x 24 in)


Electrical Specifications

Model

Amperage

Short Circuit Current Rating (SCCR)

Max Voltage

Input Pulse Amplitude, E1, E2

Residual Requirement Amplitude and Filter Residual Let Through

Typical Filter Response

HEMP-2010

10

10 k A

277/480

2500 A; 250 A

<10 A

No Filter Damage or Performance Degradation

HEMP-2030

30

25 k A

277/480

2500 A; 250 A

<10 A

No Filter Damage or Performance Degradation

HEMP-3030

30

25 k A

277/480

2500 A; 250 A

<10 A

No Filter Damage or Performance Degradation

HEMP-4030

30

25 k A

277/480

2500 A; 250 A

<10 A

No Filter Damage or Performance Degradation

HEMP-2060

60

25 k A

277/480

2500 A; 250 A

<10 A

No Filter Damage or Performance Degradation

HEMP-3060

60

25 k A

277/480

2500 A; 250 A

<10 A

No Filter Damage or Performance Degradation

HEMP-4060

60

25 k A

277/480

2500 A; 250 A

<10 A

No Filter Damage or Performance Degradation

HEMP-2100

100

25 k A

277/480

2500 A; 250 A

<10 A

No Filter Damage or Performance Degradation

HEMP-3100

100

25 k A

277/480

2500 A; 250 A

<10 A

No Filter Damage or Performance Degradation

HEMP-4100

100

25 k A

277/480

2500 A; 250 A

<10 A

No Filter Damage or Performance Degradation

HEMP-3250

250

25 k A

277/480

2500 A; 250 A

<10 A

No Filter Damage or Performance Degradation

HEMP-4250

250

25 k A

277/480

2500 A; 250 A

<10 A

No Filter Damage or Performance Degradation

HEMP-3X400

400

50 k A

277/480

2500 A; 250 A

<10 A

No Filter Damage or Performance Degradation

HEMP-4X400

400

50 k A

277/480

2500 A; 250 A

<10 A

1No Filter Damage or Performance Degradation

HEMP-3X600

600

125 k A

277/480

2500 A; 250 A

<10 A

No Filter Damage or Performance Degradation

HEMP-4X600

600

125 k A

277/480

2500 A; 250 A

<10 A

No Filter Damage or Performance Degradation

HEMP-3X800

800

125 k A

277/480

2500 A; 250 A

<10 A

No Filter Damage or Performance Degradation n

HEMP-4X800

800

125 k A

277/480

2500 A; 250 A

<10 A

No Filter Damage or Performance Degradation

HEMP-3X1200

1200

150 k A

277/480

2500 A; 250 A

<10 A

No Filter Damage or Performance Degradation

HEMP-4X1200

1200

150 k A

277/480

2500 A; 250 A

<10 A

No Filter Damage or Performance Degradation


Product Options


Product Configuration