Key Features
- Ultra Broadband Frequency Range: 26 MHz - 40 GHz
- Radiated Immunity Compliance
-- IEC 61000-4-3
- Radiated Emissions Pre-Compliance
-- Semi Anechoic (Pre-Scan)
-- ANSI C63.4/CISPR 16-1-4
-- Fully Anechoic
&nbps; -- CISPR 16-1-4 (Fixed height)
- Turnkey Chamber Solutions
Description
SPACESAVER PC
A semi-anechoic chamber, the
SpaceSaver PC is designed to perform
ANSI C63.4/CISPR 16-1-4 and
IEC 61000-4-3 pre-compliant radiated
immunity measurements.
This chamber can also be used for
ANSI C63.4 pre-compliant radiated
emissions measurement prescans,
with limited height scan.
Frequency ranges for this chamber
are 80 MHz to 40 GHz (radiated
immunity) and 30 MHz to 40 GHz
(radiated emission).
SPACESAVER 26H
A semi-anechoic chamber, the
SpaceSaver 26H is designed to perform
ANSI C63.4/CISPR 16-1-4 and
IEC 61000-4-3 compliant radiated
immunity measurements.
This chamber can also be used for
ANSI C63.4 pre-compliant radiated
emissions measurement prescans,
with limited height scan.
Frequency ranges for this chamber
are 26 MHz to 40 GHz (radiated
immunity) and 30 MHz to 40 GHz
(radiated emission).
SPACESAVER FAR
A fully anechoic chamber, the
SpaceSaver FAR is designed to
perform IEC 61000-4-3 compliant
radiated immunity measurements.
This chamber can also be used
for CISPR 16-1-4 pre-compliant
radiated emissions measurement
prescans, with fixed height.
Frequency ranges for this chamber
are 26 MHz to 40 GHz (radiated
immunity) and 30 MHz to 40 GHz
(radiated emission).
Standard Configuration
- Two Connector Panels, 15 cm x 61 cm
(6” x 24”) Clear Opening
- Four corner-mounted light fixtures with floodlights (electrical distribution not included)
- 4 x 2 x 30 Amp, Power-Line Filters For
Lights And EUT (Wiring Not Included)
- One single-leaf, Series 201, recessed contact mechanism (RCM), manually operated, RF-shielded door, 0.91 m x 2.13 m (3' x 7') clear opening
- Two waveguide vents, 30.48 cm x 30.48 cm (12' x 12') in the ceiling
- Shield Test Per IEEE-299/MIL-STD 285
- One 3.81 cm (1.5") pipe penetration with flange nuts and cap
- 7-TR Tripod (Baseline on SpaceSaver
26H and SpaceSaver FAR, Optional on
SpaceSaver PC)
- 4 x Corner-Mounted Light Fixtures With
Floodlights (Electrical Distribution Not
Included)
- Two "N" type connectors
- One 4 cm (1.5”) Pipe Penetration With
Flange Nuts And Cap
Options
- Sliding doors for flush-threshold opening
- Fire detection and suppression systems
- Immunity Interlock Switch
- Chamber Testing (See Performance Tables)
- Heating, Ventilation, & Air Conditioning (HVAC) Systems
- Electrical distribution
- CCTV monitoring system
- Raised reflective ground plane floor system
- Various sizes of series 201 RF shielded swing doors
- Intercom system
- Structural design calculations and certification
- Additional filtering
- Polystyrene Wall Covering Over Ferrite
- Antennas
-- Immunity Only
-- 3109 Biconical
-- 3148B Log Periodic
-- Emissions Only
-- 3110C Biconical
-- 3148B Log Periodic
-- Immunity and Emissions
-- 3104C Biconical (50 w max.)
-- 3148B Log Periodic
-- 3142D Log Periodic - Towers and Tripods
-- Immunity Only
-- 4-TR Tripod
7-TR Tripod (SpaceSaver PC)
-- Immunity and Emissions
2175-2 MiniMastTM - Positioners
-- Low Reflective Table
-- 2165-1.21, LoPro 1.2 m diameter
-- 2188-1.23, 1.2 m diameter
(requires 160 mm (6”) raised floor)
-- 2188-1.53, 1.5 m diameter
(requires 160 mm (6”) raised floor) - Probes
-- HI-6005
-- HI-6105
Electrical Specifications
|
Frequency Minimum |
26 MHz
|
|
Frequency Maximum |
40 GHz
|
Physical Specifications
|
Scan Height |
1 m - 2 m
|
|
Overall Structure Dim (H) |
3.2 m
(10.50 ft)
|
|
Overall Structure Dim (L) |
7.8 m
(25.59 ft)
|
|
Overall Structure Dim (W) |
3.8 m
(12.47 ft)
|
|
Internal Working Area (L) |
7.6 m
(24.93 ft)
|
|
Internal Working Area (W) |
3.1 m
(10.17 ft)
|
|
Internal Working Area (H) |
3.1 m
(10.17 ft)
|
|
Quiet Zone for Emission Testing (Diameter x H) |
1.2 m x 2.0 m 3.9 ft x 6.6 ft
|
|
Field Uniformity |
0 to 6 dB 1.5 m x 1.5 m
|