Solutions for


Find a Rep or Distributor

Home /  Categories /  Chambers / 

SpaceSaver™ 26H Chamber

SpaceSaver™ 26H Chamber

A semi-anechoic chamber, the SpaceSaver 26H is designed to perform ANSI C63.4/CISPR 16-1-4 and IEC 61000-4-3 compliant radiated immunity measurements.
Ask a Question Ask a Question

Print Version Print Version
SpaceSaver26H Datasheet Product Datasheet

Key Features

  • Ultra Broadband Frequency Range: 26 MHz - 40 GHz
  • Radiated Immunity Compliance
    -- IEC 61000-4-3
  • Radiated Emissions Pre-Compliance
    -- Semi Anechoic (Pre-Scan)
      -- ANSI C63.4/CISPR 16-1-4

    -- Fully Anechoic
    &nbps; -- CISPR 16-1-4 (Fixed height)
  • Turnkey Chamber Solutions

Description

SPACESAVER PC

A semi-anechoic chamber, the SpaceSaver PC is designed to perform ANSI C63.4/CISPR 16-1-4 and IEC 61000-4-3 pre-compliant radiated immunity measurements.

This chamber can also be used for ANSI C63.4 pre-compliant radiated emissions measurement prescans, with limited height scan.

Frequency ranges for this chamber are 80 MHz to 40 GHz (radiated immunity) and 30 MHz to 40 GHz (radiated emission).

SPACESAVER 26H

A semi-anechoic chamber, the SpaceSaver 26H is designed to perform ANSI C63.4/CISPR 16-1-4 and IEC 61000-4-3 compliant radiated immunity measurements.

This chamber can also be used for ANSI C63.4 pre-compliant radiated emissions measurement prescans, with limited height scan.

Frequency ranges for this chamber are 26 MHz to 40 GHz (radiated immunity) and 30 MHz to 40 GHz (radiated emission).

SPACESAVER FAR

A fully anechoic chamber, the SpaceSaver FAR is designed to perform IEC 61000-4-3 compliant radiated immunity measurements.

This chamber can also be used for CISPR 16-1-4 pre-compliant radiated emissions measurement prescans, with fixed height.

Frequency ranges for this chamber are 26 MHz to 40 GHz (radiated immunity) and 30 MHz to 40 GHz (radiated emission).

Standard Configuration

  • Two Connector Panels, 15 cm x 61 cm (6” x 24”) Clear Opening
  • Four corner-mounted light fixtures with floodlights (electrical distribution not included)
  • 4 x 2 x 30 Amp, Power-Line Filters For Lights And EUT (Wiring Not Included)
  • One single-leaf, Series 201, recessed contact mechanism (RCM), manually operated, RF-shielded door, 0.91 m x 2.13 m (3' x 7') clear opening
  • Two waveguide vents, 30.48 cm x 30.48 cm (12' x 12') in the ceiling
  • Shield Test Per IEEE-299/MIL-STD 285
  • One 3.81 cm (1.5") pipe penetration with flange nuts and cap
  • 7-TR Tripod (Baseline on SpaceSaver 26H and SpaceSaver FAR, Optional on SpaceSaver PC)
  • 4 x Corner-Mounted Light Fixtures With Floodlights (Electrical Distribution Not Included)
  • Two "N" type connectors
  • One 4 cm (1.5”) Pipe Penetration With Flange Nuts And Cap

Options

  • Sliding doors for flush-threshold opening
  • Fire detection and suppression systems
  • Immunity Interlock Switch
  • Chamber Testing (See Performance Tables)
  • Heating, Ventilation, & Air Conditioning (HVAC) Systems
  • Electrical distribution
  • CCTV monitoring system
  • Raised reflective ground plane floor system
  • Various sizes of series 201 RF shielded swing doors
  • Intercom system
  • Structural design calculations and certification
  • Additional filtering
  • Polystyrene Wall Covering Over Ferrite
  • Antennas
    -- Immunity Only
      -- 3109 Biconical
      -- 3148B Log Periodic
    -- Emissions Only
      -- 3110C Biconical
      -- 3148B Log Periodic
    -- Immunity and Emissions
      -- 3104C Biconical (50 w max.)
      -- 3148B Log Periodic
      -- 3142D Log Periodic
  • Towers and Tripods
    -- Immunity Only
      -- 4-TR Tripod
      7-TR Tripod (SpaceSaver PC)
    -- Immunity and Emissions
      2175-2 MiniMastTM
  • Positioners
    -- Low Reflective Table
    -- 2165-1.21, LoPro 1.2 m diameter
    -- 2188-1.23, 1.2 m diameter
      (requires 160 mm (6”) raised floor)
    -- 2188-1.53, 1.5 m diameter
      (requires 160 mm (6”) raised floor)
  • Probes
    -- HI-6005
    -- HI-6105

Electrical Specifications

Frequency Minimum 26 MHz
Frequency Maximum 40 GHz

Physical Specifications

Scan Height 1 m - 2 m
Overall Structure Dim (H) 3.2 m   (10.50 ft)
Overall Structure Dim (L) 7.8 m   (25.59 ft)
Overall Structure Dim (W) 3.8 m   (12.47 ft)
Internal Working Area (L) 7.6 m   (24.93 ft)
Internal Working Area (W) 3.1 m   (10.17 ft)
Internal Working Area (H) 3.1 m   (10.17 ft)
Quiet Zone for Emission Testing (Diameter x H) 1.2 m x 2.0 m
3.9 ft x 6.6 ft
Field Uniformity 0 to 6 dB
1.5 m x 1.5 m
USA FINLAND UK FRANCE CHINA JAPAN ONLINE
Tel +1.512.531.6400 Tel +358.2.8383.300 Tel +44(0)1438.730700 Tel +33.1.48.65.34.03 Tel +8610.8275.5086 Tel+ 81.3.3813.7100 info@ets-lindgren.com
Fax +1.512.531.6500 Fax +358.2.8651.233 Fax +44(0)1438.730751 Fax +33.1.48.65.43.69 Fax +8610.8275.5537 Fax +81.3.3813.8068 www.ets-lindgren.com

Information presented is subject to change as product enhancements are made. Contact ETS-Lindgren Sales Department for current specification.